BATTERY
The sealed battery does not require any mainte-
nance. When electrolyte leaks, or other failure of
the electrical system is detected, apply to the SWM
Dealer.
If the vehicle remains unused for long periods, it is
recommended to disconnect the battery from the
electrical system and store it in a dry place.
- After an intensive use of the battery, it is advis-
able to carry out a standard slow charging cycle
(12V-6Ah battery: 0,6A for 8 hours).
- Quick charging is advised only in situations of ex-
treme necessity since the life of lead elements is
drastically reduced by such cycle (12V-6Ah battery:
6A for 0,5 hours).
BATTERY CHARGER
To gain access to the battery (1):
- first turn counterclockwise fastening rear pin (2)
then remove the saddle.
- Release the elastic strap holding the battery;
- first remove the BLACK negative cable, then the
RED positive cable (when reassembling, first con-
nect the RED positive cable, then the BLACK nega-
tive cable);
- remove the battery (1) from its housing.
Check, using a voltmeter, that battery voltage is not
less than 12.5 V.
If it is not so, the battery needs to be charged.
Using a battery charger with a constant voltage,
first connect the RED positive cable to the battery
positive terminal then the BLACK or BLUE negative
cable to the battery negative terminal.
The voltage reaches a constant value only after a
few hours, therefore it is suggested NOT to meas-
ure it immediately after having charged or dis-
charged the battery.
Always check the battery charge before reinstalling
it on the vehicle.
The battery should be kept clean and the terminals
coated with grease.
The battery can be charged also with a charge
maintainer, by connecting it to the auxiliary socket
connector [connector (18) on page 60].
2
WARNING*: The battery contains sulphuric
acid. Avoid contact with skin, eyes or clothing.
SOLUTIONS:
CONTACT WITH THE SKIN: Rinse with plenty of
water.
INGESTION: Drink large amounts of water. Im-
mediately call a doctor. Do not induce vomit-
ing.
CONTACT WITH THE EYES: Flush with water for
no less than 15 minutes and get prompt medi-
cal attention.
WARNING*: If the battery is left unused, it has
to be in any case recharged with slow cycle
(12V-6Ah battery: 0,6A for 8 hours) at least
every 3 weeks.
WARNING*: Batteries produce explosive gas,
ventilate when charging or using indoors.
When using a battery charger, always connect
the battery before turning on the charger. This
procedure prevents sparks at the battery ter-
minals which could ignite any battery gases.
1
EN - 67