Query counter status
Send a SMS with the content
AT**out2=pulse01
to query the meter readings. The RDS1
sends a SMS response with the content:
Sample station: XX/YYYY OK:1
Sample station:
Set collective message
XX:
current reading of the daily washes counter
YYYY:
current reading of the total washes counter
OK:1:
The washing unit is ready-to-use
OK:0:
If a malfunction has occurred, the washing
bay is not operational.

Functions self-service plants

SB C Relaunch, SB M, SB MU, SB
MB
Note:
The RDS1 must be switched on to ex-
change information between the SB wash-
ing unit and the mobile phone.
Fault message
If malfunctions occur on the self-service
plant, the RDS1 sends a SMS to the listed
recipients with a delay of 60 seconds.
The SMS has the following format:
Sample station F:222=MS pump WW
This means:
Sample station:
Set collective message
F:222=MS pump WW:
Error message (example)
The meaning of the indicated malfunction
can be looked up in Chapter "Fault mes-
sages" in the operating instructions of the
self-service plant.
If there is no display text available in the lo-
cal language, only the error code (F:XXX)
is sent.
If the system is locked due to a malfunction,
the message in the second line of the SMS
contains the information "System locked".
After all malfunctions have been rectified,
the RDS1 sends the following message:
Sample system no error
12
Query coins counter total sales
Send a SMS with the content
AT**out2=pulse01
to query the total meter readings. The
RDS1 sends a SMS response with the con-
tent:
Sample station:
1=aaaaaaaa,aa
2=bbbbbbbb,bb
3=cccccccc,cc
4=ddddddd,dd
5=eeeeeeee,ee
6=ffffffff,ff
7=ggggggg,gg
8=hhhhhhh,hh
Sample station:
Set collective message
1 ( to 8) =aaaaaaa,aa:
Total turnover washing station (1-8)
Display 1 to 8 depends on the number of
washing stations.
Query coins counter daily sales
Send a SMS with the content
AT**out2=pulse02
to query the meter readings. The RDS1
sends a SMS response with the content:
Sample station:
1=aaaaaaaa,aa
2=bbbbbbbb,bb
3=cccccccc,cc
4=ddddddd,dd
5=eeeeeeee,ee
6=ffffffff,ff
7=ggggggg,gg
8=hhhhhhh,hh
Sample station:
Set collective message
1 ( to 8) =aaaaaaa,aa:
Total turnover washing station (1-8)
Display 1 to 8 depends on the number of
washing stations.
4
-
EN

Functions CP

CP exchange solution
Note:
The RDS1 must be switched on to ex-
change information between the washing
bay and the mobile phone.
Fault message
If malfunctions occur on the CP, the RDS1
sends a SMS to the listed recipients with a
delay of 60 seconds.
The SMS has the following format:
Sample system, 001, 002
This means:
Sample station:
Set collective message
001, 002:
Error 001, 002 occurred
The meaning of the indicated malfunction
can be looked up in Chapter "Fault mes-
sages" in the operating instructions of the
CP system.
After all malfunctions have been rectified,
the RDS1 sends the following message:
Muster Anlage NO FAULTS
Query coins counter
Send a SMS with the content
AT**out2=pulse01
to query the meter readings. The RDS1
sends a SMS response with the content:
Sample station:
XXX/YYYY
UNIT OPEN
NO FAULTS
Sample station:
Set collective message
XX:
current reading of the daily coin counter
YYYY:
current reading of the total coin counter
UNIT OPEN:
Release washing operations
UNIT CLOSED:
Washing operations locked
NO FAULTS:
No disturbances of the CP system
001, 002
Malfunction 001 and 002 have occurred in
the CP washing bay
Display 1 to 8 depends on the number of
washing stations.