7.9.4
Menu 04 - STANDBY MODE
[Menu 04] allows you to activate or deactivate the standby function.
To access the menu, press [P3], then press [P1] or [P2] to activate
("on") or deactivate ("off") the standby mode.
Press [P4] to exit.
The standby function turns off the appliance when the ambient temperature is 3° C higher than the set temperature for
more than three minutes. The screen displays the message [WAIT OFF]. During this phase, the appliance stops the
auger. The smoke extractor remains on until the cooling is complete.
The appliance turns on again as soon as the ambient temperature drops 1° C below the set temperature.
7.9.5
Menu 05 - ALARM
[Menu 5] allows you to activate or deactivate the alarms.
To access the menu, press [P3], then press [P1] or [P2] to activate
("on") or deactivate ("off") the alarm.
Press [P4] to exit.
7.9.6
Menu 06 - INITIAL LOAD
[Menu 06] is used to pre-load the auger. This function is available when the appliance is turned [OFF]. This pre-loading
lasts 180 seconds. One or two refills of the auger are required in the following cases:
3. After an alarm due to a lack of pellets: "PELLETS EMPTY" (empty hopper). = a pre-load is necessary.
4. During commissioning or following a complete cleaning of the hopper after a heating season (ex: with a vacuum
cleaner) = Two pre-loads are required.
Note: You can start a pre-load via the main screen (OFF position) by pressing [P1] and [P2] simultaneously.
To access the menu, press [P3], then press [P1] or [P2] to launch the
180-second pre-load in the auger.
To stop the pre-load if too many pellets are added, press the [P4] key.
7.9.7
Menu 07 - STOVE STATUS
This function is reserved for qualified professionals. It allows them to
see the status of certain settings when the appliance is in operation.
SP 06 04 2018
Poêle Cannelé Plug-in
Références P642151 & P642152
Page 28 sur
47