Poêle Cannelé Plug-in
Références P642151 & P642152
When the room temperature has reached the required value, the
power level automatically changes to the minimum value (Power 1).
Under these conditions, the screen will display [MODULE].
If the room temperature falls below the required value, the appliance
returns to the required operating power (Power 5 in this case).
MANUAL MODE:
By setting the room temperature above 40°C, [Man] will appear on the display and the appliance will switch to manual
mode, keeping the maximum operating power level set without going down to the minimum, regardless of the room
temperature: there is no more modulation.
THERMOSTAT MODE:
By setting the room temperature below 6°C, [therm] will appear on the display and the appliance will switch to
external thermostat mode. This mode allows the appliance to turn on and off using a thermostat or external switch
that is connected to the corresponding terminal on the appliance's electronic board (see section 5.4).
Once the thermostat mode is activated, the ignition request by the
external thermostat will be confirmed by activating the
corresponding activation LED at the top left of the screen.
SP 06 04 2018
Page 21 sur
47