Installation

Pos: 80 /Technische Dokumentation/Betriebsanleitung/Installation/Installation @ 0\mod_1427869040467_370.docx @ 27032 @ 1 @ 1
5
Installation
Pos: 81 /Technische Dokumentation/Betriebsanleitung/Installation/Einbauort/Einbauort @ 0\mod_1427869486488_370.docx @ 27047 @ 2 @ 1
5.1

Installation site

Pos: 82 /Technische Dokumentation/Betriebsanleitung/Installation/Einbauort/Aufstellen im Freien @ 0\mod_1427869735350_370.docx @ 27062 @ 3 @ 1
5.1.1

Outdoor installation

In order to increase the pump's service life, provide simple
weather protection.
Pos: 83 /Technische Dokumentation/Betriebsanleitung/Installation/Einbauort/Bodenablauf muss vorhanden sein @ 0\mod_1427870166005_370.docx @ 27077 @ 3 @ 1
5.1.2

There must be ground drainage

Calculate the size of the ground drain according to the
following criteria:
– Size of the swimming pool.
– Circulation flow rate.
Pos: 84 /Technische Dokumentation/Betriebsanleitung/Installation/Einbauort/Be- und Entlüftung @ 0\mod_1427870979088_370.docx @ 27092 @ 3 @ 1
5.1.3

Ventilation and aeration

Ensure sufficient ventilation and aeration. The ventilation and
aeration must ensure the following conditions:
– Prevention of condensation.
– Minimum distance from fan cover to the wall: 50 mm.
– Cooling of the pump motor and other system components,
for example switch cabinets and control units.
– Limitation of the ambient temperature to maximum 40 °C.
Pos: 85 /Technische Dokumentation/Betriebsanleitung/Installation/Einbauort/Körper- und Luftschallübertragung @ 0\mod_1427873018962_370.docx @ 27107 @ 3 @ 1
5.1.4

Structure-borne and airborne noise transmission

Observe regulations for structural noise protection, for
example DIN 4109.
Install the pump in a manner which reduces structure-borne
and airborne noise transmission. Vibration-absorbing
materials are suitable bases. Examples:
– Anti-vibration buffers
– Cork lining
– Sufficiently hard foam
Pos: 87 /Technische Dokumentation/Betriebsanleitung/Installation/Einbauort/Platzreserve @ 0\mod_1427876785998_370.docx @ 27122 @ 3 @ 1
5.1.5

Reserve space

Provide enough reserve space to remove the motor unit
backwards from the pump in the direction of the motor fan
and the strainer basket upwards. See dimensional drawing in
the pump data sheet.
Pos: 88 /Technische Dokumentation/Betriebsanleitung/Installation/Einbauort/Befestigungselemente @ 0\mod_1427877318034_370.docx @ 27137 @ 3 @ 1
5.1.6

Fasteners

Fasten pump using screws.