Settings
Designation
Wire speed
Voltage
Self
Point
Pre-gas
Post gaz
Thickness
Arc length
Current
Access to some welding parameters depends on the selected display mode: Settings/User Level: Easy, Expert, Advanced.
• DELAY
This is a pointing mode similar to SPOT, but with a combination of pointing and stopping time defined as long as the trigger is held in.
Settings
Designation
Wire speed
Voltage
Point
Duration between 2
spots
Self
Pre-gas
Post gaz
Thickness
Arc length
Current
Access to some welding parameters depends on the selected display mode: Settings/User Level: Easy, Expert, Advanced.
NEOPULSE 220 C / 220 C XL
Adjustable
settings
0.5 - 20m/min
Quantity of filler metal deposited and indirectly the welding intensity.
10 - Umax
Sets the welding power.
Smoothes more or less the welding current. To be adjusted according to the welding
-4 > +4
position.
0.1 - 10 secs.
Defined duration.
0 - 25 secs.
Torch purge time and to protect the area with gas before ignition
Duration for which gas is released after the arc has stopped. It protects the weld pool
0 - 25 secs.
and the electrode against oxidisation when the metal is cooling down.
The synergy allows for fully automatic settings. The thickness action automatically
0.1 - 5.5 mm
sets the tension and the appropriate yarn speed.
Used to adjust the distance between the end of the wire and the weld (voltage
-6 > +6
adjustment).
The welding current is adjusted according to the type of wire used and the mate-
15 - Imax
rial to be welded.
Adjustable
settings
0.5 - 20m/min
Quantity of filler metal deposited and indirectly the welding intensity.
10 - Umax
Adjusts the welding power
0.1 - 10 secs.
Defined duration.
Time between the end of a spot (excluding Post gas) and the start of a new spot (including
0.1 - 10 secs.
Pre-Gas).
Smoothes more or less the welding current. To be adjusted according to the welding
-4 > +4
position.
0 - 25 secs.
Torch purge time and to protect the area with gas before ignition
Duration for which gas is released after the arc has stopped. It protects the weld pool and
0 - 25 secs.
the electrode against oxidisation when the metal is cooling down.
The synergy allows for fully automatic settings. The thickness action automatically
0.1 - 5.5 mm
sets the tension and the appropriate yarn speed.
Used to adjust the distance between the end of the wire and the weld (voltage
-6 > +6
adjustment).
The welding current is adjusted according to the type of wire used and the mate-
15 - Imax
rial to be welded.
Description & advice
Description & advice
EN
37