Equipment Installation; Maintenance / Recommendations - GYS NEOPULSE 220 C Mode D'emploi

Masquer les pouces Voir aussi pour NEOPULSE 220 C:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

protection of the entire welding area can be considered for specific situations.
TRANSPORT AND TRANSIT OF THE WELDING MACHINE
The machine is fitted with handle(s) to facilitate transportation. Be careful not to underestimate the machine's weight. The handle(s) cannot be used
for slinging.
Do not use the cables or torch to move the machine. The welding equipment must be moved in an upright position.
Do not place/carry the unit over people or objects.
Never lift the machine while there is a gas cylinder on the support shelf. A clear path is available when moving the item.
The removal of the wire reel from the machine is recommended before undertaking any lifting operation.

EQUIPMENT INSTALLATION

• Put the machine on the floor (maximum incline of 10°.)
• Ensure the work area has sufficient ventillation for welding, and that there is easy access to the control panel.
• The machine must not be used in an area with conductive metal dusts.
• The machine must be placed in a sheltered area away from rain or direct sunlight.
- The equipment is IP23S protection degree, meaning :
- protection against access to dangerous parts of solid bodies with diam >12.5 mm and,
- protection against rain directed at 60° to the vertical when the moving parts of the device are not yet in operation.
This equipment can therefore be stored outdoors in accordance with protection class IP23S.
The power cables, extensions and welding cables must be fully uncoiled to prevent overheating.
The manufacturer does not incur any responsability regarding damages to both objects and persons that result from an incorrect
and/or dangerous use of the machine.
Stray welding currents/voltages may destroy earth conductors, damage electrical equipment or cause components to warm up which
may cause a fire.
• All welding connections must be firmly secured, check regularly !
• Check that the metal piece fixation is strong and without any electrical problems !
• Attach or hang all the electrically conductive elements, such as the trolley and slinging equipment, in order to insulate them
• Do not place any electrical equipment, such as drills or grinders, on top of the welding machine without insulating them !
• Always place welding torches or electrodes holders on an insulated surface when they're not in use !

MAINTENANCE / RECOMMENDATIONS

• Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.
• Ensure the machine is unplugged from the mains, and wait for two minutes before carrying out maintenance work. DANGER
High Voltage and Currents inside the machine.
• Remove the casing 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical connections checked by a qualified
person, with an insulated tool.
• Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, its after sales
service or an equally qualified person.
• Ensure the ventilation holes of the device are not blocked to allow adequate air circulation.
• Do not use this equipment to thaw pipes, to charge batteries, or to start any engine.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorized by the manufacturer should perform the installation of the welding equipment. During set up,
the operator must ensure that the machine is unplugged. It is recommended to use the welding cables supplied with the unit in
order to obtain the optimum product settings.
DESCRIPTION
The NEOPULSE is a single-phase portable generator for semi-automatic «synergic» welding (MIG or MAG), coated electrode welding (MMA) and
filler electrode welding (TIG). The NEOPULSE 220 C will take Ø 200 mm wire reels. The NEOPULSE 220 C XL will take Ø 200 and 300 mm wire reels.
EQUIPMENT DESCRIPTION (FIG-1)
1-
Gas connector
2-
Cable gland (mains cable)
3-
ON / OFF switch
4-
Reel support
5-
USB connector
6-
Rocker switch wire feed / gas purge
NEOPULSE 220 C / 220 C XL
7-
Wirefeed motor
8-
MMI
9-
Push-Pull torch connector
10-
Euro connector
11-
Positive polarity plug
12-
Negative polarity plug
13-
Polarity reversal cable
EN
31

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Neopulse 220 c xl

Table des Matières