Product Maintenance; Disposal Of The Product; Product Technical Features - Nice SFAB2024 Instructions Et Avertissements Pour L'installation Et L'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
ATTENTION! – Before carrying out any check, disconnect any electrical
power input source.
5.1 - Inspection
Each individual component of the automation, e.g. sensitive edges, photocells,
emergency stop etc requires a specific inspection phase. For these devices
the procedures given in the respective instruction manuals must be performed.
For the SFAB(...) inspection, proceed as follows:
1 Check that everything envisioned in chapter 1 - General safety warnings
and precautions, is rigorously respected.
2 Close the gate.
3 Remove any electric power input source to the control unit.
4 Release the gear motor using the relative wrench, see paragraph 3.6.
5 Open the panel manually until the maximum opening position is reached
and check that there is no friction during the movement.
6 Check that the panel, left in any position of its run, does not move.
7 Check that the safety systems and the mechanical stops are in good work-
ing order.
8 Check that the screw connections are well-fastened.
9 If necessary, clean the inside of the foundation case and check that the
water drain functions correctly.
10 Block the gear motor using the relative wrench, see paragraph 3.6.
11 Apply the electric power input to the control unit.
12 Measure the impact force according to the EN 12445 and EN 12453
standards. If the control of the "driving force" is used by the control unit as
an auxiliary to the system for the reduction of the force of impact, try and
adjust the functions that offer better parameters.
13 Permanently fix a label, which describes how to manually release the gear
motor, in a zone adjacent to the automation.
5.2 - Commissioning
Commissioning can only be performed after all of the inspection phases of
the gear motor and other devices present have been performed with positive
results. For commissioning refer to the control unit instruction manual.
IMPORTANT – Partial commissioning or in "temporary" situations is
prohibited.
6

PRODUCT MAINTENANCE

Maintenance must be performed in strict observance of the safety provi-
sions in this manual and according to current legislation and standards.
The automation devices do not require special maintenance. However a check
should be performed at least every six months to ensure complete efficiency
of all devices.
For this purpose, the tests and checks envisaged in paragraph 5.1 "Testing"
should all be performed, as well as all procedure in the paragraph "Maintenance
operations permitted for the user".
If other devices are present, follow the instructions in the relative maintenance
schedule.

DISPOSAL OF THE PRODUCT

This product is an integral part of the automation and therefore must
be demolished with it.
As for installation, the plant must also be demolished by qualified staff at the
end of its life span.
This product is made up of various types of materials: some can be re-cycled,
others must be disposed of. Obtain information regarding recycling or disposal
systems envisioned by the Standards in force on your territory for this category
of product.
Attention! – some parts of the product can contain pollutant or dangerous
substances which, if dispersed into the environment, could have damaging
effects on the same and human health.
As indicated by the symbol at the side, it is prohibited to throw
this product into domestic waste. "Separate collection" must be
performed for disposal, according to the methods envisioned by
the Regulations in force on your territory or take the product back
to your dealer on the purchase of a new equivalent product.
Attention! – local regulations in force may envision heavy sanctions if this
product is disposed of abusively.

PRODUCT TECHNICAL FEATURES

RECOMMENDATIONS: • All technical features stated make reference at a
room temperature of 20°C (± 5°C). • Nice S.p.A. reserves the right to modify
the product at any time it deems necessary, however maintaining the same
functionality and destination of use.
n Type: Electro-mechanical dear motors for gates and doors with hinged panels
n Power input: 24 V
n Peak absorption: 5 A
n Maximum absorption: 2 A
n Peak power: 120 W
n Maximum power: 50 W
n Protection rating: IP 67
n Run: from 0° to 90° (±10°) or from 0° to 180° (±10°) [intermediate openings
between 90° and 180° are not possible]
n Idle speed: 1.25 rpm
n Speed at nominal torque: 1 rpm
n Maximum torque: 250 Nm
n Nominal torque: 120 Nm
n Functioning temperature: -20 °C ... +50 °C
n Cycles/hour at the nominal torque: 60
n Duration: Estimated between about 80.000 and 200.000 manoeuvre
cycles, according to the conditions given in Table 1
n Dimensions: 230 mm x 206 mm x h 88 mm
n Weight: 15 kg (gear motor with foundation space)
English – 3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sfab2124

Table des Matières