4. MAINTENANCE OPERATIONS. RECOMMENDATIONS.
GOOD MAINTENANCE OF THE EQUIPMENT WILL PREVENT A LARGE PERCENTAGE OF FAULTS.
Before carrying out any operations on the machine place the general switch to "0" position and disconnect the
machine from the mains
Any interventions to the machine to carry out maintenance and repair operations must be performed by
authorised personnel. The recommended frequencies presuppose frequent use of the machine.
VERIFICATION FREQUENCY
IN EACH USE
WEEKLY
3 MONTHS
F
WARNING! SUFFICIENTLY SEPARATE THE MACHINE FROM THE WORKSTATION.
GALA CUT 350 K G.E.
Verify the state and appropriateness of the accessories for the
work to be carried out.
The torch has a safety switch. Verify that indicator 6 never lights
up when the nozzle-support has been removed, after pressing
the torch.
The machine ventilations must be kept free. The machine must
be placed in a location where there is air renewal.
Verify that the power supply and torch hose insulations have not
suffered damage. The cutting process gives off materials at
high temperatures that may harm them.
PREVENT METAL DUST ENTERING THE EQUIPMENT.
Blow the inside of the machine with compressed air
Cleaning air filters