2. TRANSPORTATION AND INSTALLATION.
2.1. TRANSPORTATION
2.2. ELECTRICAL INSTALLATION.
The location shall comply with the following requisites:
- Place: dry and ventilated.
contaminants, caused by the work process, entering the equipment. Never work in the rain.
- The distribution panel where the machine should be connected, must have the following elements, at least:
DIFFERENTIAL CIRCUIT BREAKER (ID): Bi-polar or Tri-polar with a minimum sensitivity of 300 mA. The mission
of this device is to protect people from direct or indirect contact with electrical parts under power. The differential
circuit breaker is selected in accordance with the characteristics plate.
AUTOMATIC CIRCUIT BREAKER (IA):
characteristics plate (25 A recommended).
IMPORTANT! Verify that the wire is connected to a plug with an efficient ground.
Any supply voltage that is outside the nominal margin gives rise to the activation of the protection system,
preventing the welding operation.
LENGTH
Up to 15 m
>15 m Up to 50 m
ELECTRICAL INSTALLATIONS SHOULD ONLY BE HANDLED BY SPECIALISED PERSONNEL.
BEFORE STARTING THE EQUIPMENT, VERIFY THAT THE ELECTRODE TONG IS SEPARATED
2.3. ELECTRICAL INSTALLATION TO ELECTRICAL GENERATOR SET.
The GALA CUT 350 K G.E. appliances are suitable for electrical installation to electrical generator set. These
appliances include a protection system, which continuously verifies the supply voltage, in such a way that
whenever this voltage is outside the admitted margins or is dangerously distorted, the appliance will protect itself,
by insulating the sensitive circuits of the network. Under these conditions, the appliance will remain switched off
or the amber coloured indicator, "3", will light up (see section 3). When the voltage is suitable again, the
appliance will be ready to operate.
For correct operation with electrical generator set the following minimum powers are required:
GALA CUT 350 K G.E.
SEPARATION OF THE TRANSPORT SYSTEM
STOCK CONSUMABLES FRONT AND REAR.
Far enough away from the welding position in order to prevent dust and
Bi-polar.
GALA 2000 G.E.
CROSS-SECTION
4 mm
2
6 mm
2
FROM THE WELDING MASS.
Single-phase set, Min.p = 10 KVA
The device shall be selected in accordance with the
If it is necessary to use a longer power supply
cord or a connection to an extension cord, keep
in mind the values in the following table.
Pág. 13