Accessories - TOPRO TAURUS E Basic Manuel D'instructions

Masquer les pouces Voir aussi pour TAURUS E Basic:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
EN

Accessories

For pictures and TOPRO article numbers please see the inside of the cover. Accessories mounted on the walker may
influence stability, we therefore advise you to use them carefully.
A One handed brake
B Forearm side support (pair)
C Tray
D Footplate
E Height adjustment panel
The accessories are to be ordered separately to give the possibility to compose a TOPRO TAURUS that suits the indivi-
dual users need. Contact your mobility shop, dealer or TOPRO for an updated overview of the accessories, or visit our
homepage www.topromobility.com.
In case of questions or product faults, please contact your mobility shop or dealer.
Technical details electrical components
Controller box: C3con1-x, manufacturer Concens AS, Denmark
Actuator: Con 5, manufacturer Concens AS, Denmark
Battery: C3 NiMH 24 V – 1400 mAh
Battery charger: C3-CHG-01-XX-02, Input voltage: 100–240VAC,
Class II, Input frequency: 50–60Hz, Maximum power rating:
50VA, Output voltage: 24VDC, Output current: Max 400mA, IP22.
Expected service life of the battery is 5 years under heavy use
condition according to the manufacturer.
Guidance and manufacturer's declaration
Electromagnetic EMISSIONS for all ME EQUIPMENT and ME SYSTEMS
The TOPRO TAURUS walking aid is intended for use in the electromagnetic environment specified below.
The customer or the user of the TOPRO TAURUS walking aid should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Guidance and manufacturer's declaration
Electromagnetic IMMUNITY for all ME EQUIPMENT and ME SYSTEMS
The TOPRO TAURUS is intended for use in the electromagnetic environment specified below.
The customer or the user of the TOPRO TAURUS should assure that it is used in such an environment.
Immunity test
IEC 60601 test level
Electrostatic
± 6 kV contact
discharge (ESD)
± 8 kV air
IEC 61000-4-2
Electrical fast
± 2 kV for power supply lines
transient/burst
± 1 kV for input/output lines
IEC 61000-4-4
Surge
± 1 kV line(s) to line(s)
IEC 61000-4-5
± 2 kV line(s) to earth
104801 – V2, 2021-04
TAURUS E
F Wall mount for battery charger
G Small basket
H Infusion stand
I Stand for body fluid-boxes
J Holder for oxygen
Duty Cycle: 10% maximum activation (on) time 2 minutes
and the minimum deactivation (off ) time 18 minutes.
Working ambient temperature for actuator: −5°C to +40°C
Working ambient temperature for controller and battery
charger: +5°C to +40°C
Humidity: 20–70 %
Delivery and storing ambient temperature for actuator,
controller and battery charger: −20°C to +50°C
Humidity: 20–70 %
Compliance
Group 1
Class B
Complies
Complies
Compliance level
± 6 kV contact
± 8 kV air
± 2 kV for power supply lines
± 1 kV for input/output lines
± 1 kV line(s) to line(s)
± 2 kV line(s) to earth
www.topromobility.com
Electromagnetic environment – guidance
The TOPRO TAURUS walking aid uses RF energy only for
its internal function. Therefore, its RF emissions are very
low and are not likely to cause any interference in nearby
electronic equipment.
The TOPRO TAURUS walking aid is suitable for use in all
establishments, including domestic establishments and
those directly connected to the public low voltage power
supply network that supplies buildings used for domestic
purposes.
Electromagnetic environment – guidance
Floors should be wood, concrete or cera-
mic tile. If floors are covered with synthetic
material, the relative humidity should be at
least 30 %.
Main power quality should be that of a typi-
cal commercial or hospital environment.
Main power quality should be that of a typi-
cal commercial or hospital environment.