3. Suspension from a ceiling by means of chains
 Choose 2 suspension points in the ceiling, 40 cm
apart. Ascertain that the ceiling and fastening
materials are strong enough and suitable to
take the weight of the heater for an extended
period of time.
 Fasten the suspension eyes to the ceiling (not
supplied).
 Hook one end of the chains onto suspension
points of the heater by means of the karabiner
hook. You hook the karabiner hooks at the other
end of the chain through the suspension eyes in
the ceiling. Pulling the chain through the
suspension eye and fastening the second
karabiner hook to the chain allows you to raise the suspension height of the
heater. You can also wrap the chain around a horizontal beam or rod (see
picture).
Please always take account of the minimum distances to the ceiling, floor, walls
and objects and make sure the heater is horizontal!
The following applies for all options
 However you install the Golden Amber Smart, always lead the electrical cable
directly away from the heater. It may not become hot!
 Adjust the desire radiation angle of the device. Do this by undoing both Allen
screws slightly using the Allen key. Make sure you secure them again once you
have made the adjustments! The heater can rotate through approximately 90° -
with wall fastening from 30° upwards to approximately 60° downwards. When
adjusting the angle ensure that the radiator does not radiate heat onto
flammable materials from a short distance!
 Fasten all screws another time firmly and scheck or the heater is firmly mounted.
Now your infra red heater is ready for use.
 For personal protection the installation, to which the Eurom Golden 2000 Amber
Smart is connected, has to be equipped with an earth fall device (max. 30
mAmp).
Under some circumstances it may be attractive to make a fast connection between
the heater and the main supply, and to operate the heater with a switch. Because
the Eurom Golden 2000 Amber Smart has a high water tightness (IP65) and for
safety reasons, such a connection has to be made by a qualified electrician.
Working
Check for every use:
- or the appliance doesn't show signs of damage.
- or the appliance still is fastened firmly. Mechanical bearing pressure, oscillating
duet o wind or rain could lead to loose.
- or there are no objects, canvas, sun screens etc. are inside the safety distances.