Horizontal Ducting Conversion

This range hood is equipped standard with a 8" round vertical duct option. To convert from 8" round
vertical to 8" round horizontal ducting or 3-1/4" x 10" rectangular horizontal ducting please following
the instructions below.
NOTE: Horizontal ducting is only available for the single internal blower.
NOTE: If horizontally ducting via 3-1/4" x 10" rectangular ducting, the maximum airflow of 650 CFM
will be reduced to 550 CFM. Other CFM levels will not be affected.
Tempest I Use, Care, and Installation Guide
Installation Instructions
1. Disconnect blower plug.
2. Remove (4) screws at top of
hood body attaching blower to
blower plate. Remove blower from
interior of hood body.