Minimum Mantel Clearances; Finishing - Napoleon HD81NT Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

32
5.5

MINIMUM MANTEL CLEARANCES

EN
RISK OF FIRE, MAINTAIN ALL SPECIFIED AIR SPACE CLEARANCES TO COMBUSTIBLES. FAILURE
TO COMPLY WITH THESE INSTRUCTIONS MAY CAUSE A FIRE OR CAUSE THE APPLIANCE TO
OVERHEAT. ENSURE ALL CLEARANCES (I.E. BACK, SIDE, TOP, VENT, MANTEL, FRONT, ETC.) ARE
WHEN USING PAINT OR LACQUER TO FINISH THE MANTEL, THE PAINT OR LACQUER MUST BE
Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the
clearance needed.
A
B
C
F
f i r e - p a r t s . c o m
0

6.0 FINISHING

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO
DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS
FACING AND/OR FINISHING MATERIAL MUST NEVER OVERHANG INTO THE APPLIANCE OPENING.
THE GLASS DOOR ASSEMBLY IS DESIGNED TO PIVOT FORWARD WHEN RELIEVING EXCESS
PRESSURE THAT MIGHT OCCUR. FINISHING OR OTHER MATERIALS MUST NOT BE LOCATED IN
THE OPENING SURROUNDING THE DOOR AS THIS WILL INTERFERE WITH THE DOORS ABILITY TO
W415-0687 / G / 08.26.13
CLEARLY MAINTAINED.
HEAT RESISTANT TO PREVENT DISCOLOURATION.
G
F
E
D
C
MANTEL DEPTH
NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE.
BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED.
REMOVED, CRACKED, BROKEN OR SCRATCHED.
RELIEVE THE PRESSURE.
WARNING
!
E
D
C B
A
WARNING
!
RISK OF FIRE!
73.1
MANTEL DIMENSIONS
Ref
Height
Depth
A
33 1/2" (851mm)
B
16" (406mm)
2" (51mm)
C
18" (457mm)
4" (102mm)
D
20" (508mm)
6" (152mm)
E
22" (559mm)
8" (203mm)
72.6