Control Access; Inner Access Panel; Valve Removal - Napoleon HD81NT Instructions D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Re-assemble the various components in reverse order.
Inspect the relief system. The appliance relief through the main glass door or through the fl aps on the
fi rebox top. Ensure they open freely, and close sealed.
NOTE: To install batteries in the case of a power outage you must access the
receiver. Remove the receiver cover plate and install the 4 "AA" batteries.
Ensure the 3 position slider switch is in the "REMOTE" position (middle).
11.2

CONTROL ACCESS

11.2.1 INNER ACCESS PANEL

NOTE: A new gasket will be
required, when re-installing the
access panel (see replacement
parts).
f i r e - p a r t s . c o m
Remove one of the main doors,
see "DOOR REMOVAL /
INSTALLATION" section. Remove
either the optional brick or
porcelain panel from the side
where the control box is located.
Remove the eight screws from the
access panel.

11.3 VALVE REMOVAL

The valve on the HD81 is piped with three fl ex
connectors (one inlet, two outlets). It can be removed
and pulled forward for service.
A. Remove inner access panel, see "INNER ACCESS
PANEL" section.
B. Remove the wing nut and pivot the valve out from
the slot at the bottom of the valve.
C. Slowly pull the valve through the control door
being careful not to kink the gas lines or wires.
Disconnect fl ex connectors.
D. Replace all components before
returning the appliance to service.
E. Check for gas leaks by brushing on
a soap and water solution.
ACCESS
PANEL
CONTROL BOX
37.1A
RETAINING
BRACKETS
VALVE ACCESS
HOLE
WING
NUT
VALVE
W415-0687 / G / 08.26.13
45