Expansion / contraction noises during heating up and cooling down cycles are normal and are to be expected.
Change in fl ame appearance from "HI" to "LO" is more evident in natural gas than in propane.
NOTE: The protective wrap on plated parts is best removed when
the assembly is at room temperature but this can be improved if
the assembly is warmed, using a hair dryer or similar heat source.
This appliance is equipped with a remote control system, which
requires batteries (supplied) to be installed. The transmitter takes 3
"AAA" batteries and in the case of a power failure the receiver takes 4
"AA" batteries.
2.4

RATING PLATE INFORMATION

Both the rating plate and operating instructions are riveted to the bottom of the side spacers. There is a hole in
the bottom of each mounting plate to help with rotating the plate up.
f i r e - p a r t s . c o m
LIGHTING INSTRUCTIONS / INSTRUCTIONS D'ALLUMAGE
C
WARNING:
DO NOT TURN ON IF CHILDREN OR OTHER AT RISK INDIVIDUALS ARE NEAR THE FIREPLACE.
1.
STOP! READ THE ABOVE SAFETY INFORMATION ON THIS LABEL.
2.
REMOVE THE BATTERIES FROM THE TRANSMITTER.
3.
TURN OFF ELECTRIC POWER TO THE FIREPLACE.
4.
THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS
THE PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND.
5.
OPEN THE GLASS DOOR.
6.
TURN MANUAL SHUTOFF VALVE CLOCKWISE
TO OFF. LOCATED BEHIND THE
ACCESS PANEL.
7.
WAIT FIVE (5) MINTUES TO CLEAR OUT ANY GAS. IF YOU SMELL GAS INCLUDING NEAR
THE FLOOR, STOP! FOLLOW "B' IN THE ABOVE SAFETY INFORMATION ON THIS LABEL. IF
YOU DON'T SMELL GAS, GO TO THE NEXT STEP.
8.
TURN MANUAL SHUTOFF VALVE COUNTER-CLOCKWISE
9.
CLOSE THE GLASS DOOR.
10.
TURN ON ALL ELECTRIC POWER TO THE FIREPLACE AND RE-INSTALL BATTERIES INTO
THE TRANSMITTER.
11.
PUSH THE "ON" BUTTON ON THE TRANSMITTER. YOU SHOULD HEAR AN AUDIBLE BEEP
FROM THE RECEIVER WHICH INDICATES COMMUNICATION. (REFER TO FIREPLACE
OPERATIONS FOR REMOTE ACTIVATION).
1.
TURN OFF ALL ELECTRIC POWER TO THE FIREPLACE IF SERVICE IS TO BE PERFORMED.
SERVICE IS TO BE P
ERVICE IS TO BE
2.
ACCESS DORR INSIDE THE FIREBOX MUST BE REMOVED TO ACCES THE MAIN SHUTOFF VALVE.
O ACCES THE
CCES THE
3.
TURN MANUAL SHUTOFF VALVE CLOCKWISE
TO OFF. DO NOT FORCE
F. DO NOT
F. DO NOT
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
The illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.
S D'A
AVERTISSEMENT :
EMENT :
EMENT :
NE PA
NE
NE PAS ALLUMER SI DES ENFANTS OU D'AUTRES INDIVIDUS À RISQUE SONT À PROXMITÉ
DU FOYER.
1.
ARRÊTEZ! LISEZ LES RECOMMENDATIONS DE SÉCURITÉ DE CETTE ÉTIQUETTE.
ARRÊTEZ!
TEZ!
LISEZ LES REC
LISEZ LES REC
2.
RETIREZ LES PILES DE LA TELECOMMANDE.
RETIREZ LES PILES DE
Z LES PILES DE
3.
COUPEZ L'ALIMENTAT
COUPEZ L'ALIMENTA
COUPEZ L'ALIMENTATION ÉLECTRIQUE À L'APPAREIL.
4.
4.
4.
CET APPAREIL ES
CET APPAREIL EST MUNI D'UN DISPOSITIF D'ALLUMAGE QUI ALLUME LA VEILLEUSE
CET APPAREIL EST
AUTOMATIQUE
AUTOMATIQUEMENT. N'ESSAYEZ PAS D'ALLUMER LA VEILLEUSE MANUELLEMENT.
AUTOMATIQUEM
5.
5.
5.
OUVRE LA PO
OUVRE LA PORTE VITRÉE.
OUVRE LA PO
6.
6.
6.
TOURNEZ LA SOUPAPE DE SECTIONNEMENT MANUELLE VERS LA DROITE
TOURNEZ
TOURNEZ L
DERRIÈR
DERRIÈR
DERRIÈRE LE PANNEAU D'ACCÉS.
IF
7.
7.
7.
ATTENDEZ CINQ (5) MINUTES POUR QUE LE GAZ PUISSE S'ÉCHAPPER. SI VOUS DÉTECTEZ UNE
ATTEN
ATTEN
OD
ODEUR DE GAS, ARRÊTEZ! ET OBSERVEZ L'ITEM "B" DES MESURES DE SÉCURITÉ CI-DESSUS. S'IL
N'Y A PAS D'ODEUR DE GAZ, PASSEZ À L'ÉTAPE SUIVANTE.
N
TO ON.
8.
8.
8.
TOURNEZ LA SOUPAPE DE SECTIONNEMENT MANUELLE VERS LA GUACHE
9.
9.
9.
FERMEZ LA PORTE VITRÉE.
RIES INTO
RIES INTO
10.
10
1
TOURNEZ L'INTERRUPTEUR DE L'APPAREIL ET 'INTERRUPTEUR À DISTANCE MURAL À "ON" ET
REPLACEZ LES PILES.
AUDIBLE BEEP
AUDIBLE BEEP
11.
APPUYEZ SUR LE BOUTON
«ON» DE LA TELECOMMANDE. VOUS DEVRIEZ ENTENDRE UN «BIP»
TO FIREPLACE
REPLACE
DU RÉCEPTEUR VOUS INDIQUANT QUE LA COMMUNICATION EST BONNE. (POUR ACTIVER LE
RÉCEPTEUR. RÉFÉREZ-VOUS À LA SECTION FONCTIONNEMENT DU FOYER).
TO TUR
TO TURN OFF GAS / INSTRUCTIONS POUR COUPER LE GAZ
1.
COUPEZ L'ALIMENTATION ÉLECTRIQUE AU FOYER SI UN TRAVAIL D'ENTRETIEN DOIT SE FAIRE.
2.
POUR ACCÉDER À LA SOUPAPE D'ARRÊT MANUELLE, ENLEVEZ LA PORTE D'ACCÈS SITUÉE À L'INTERIEUR DU FOYER.
3.
TOURNEZ LA SOUPAPE D'ARRÊT MANUELLE VERS LA DROITE
À « OFF ». NE FORCEZ PAS.
SIDE SPACERS
OPERATING
INSTRUCTIONS
CERTIFIED UNDER / HOMOLOGUE SELON LES NORMES: CSA 2.33 - 2009, ANSI Z21.88 - 2009 VENTED GAS FIREPLACE HEATER / APPAREIL DE CHAUFFAGE ALIMENTÉ AU GAZ ET VENTILÉ
VENTED GAS FIREPLACE HEATER. APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLA-
TION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE
MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US
STANDARD IS NOT APPLICABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
NOT FOR USE WITH SOLID FUEL.
FOR USE WITH GLASS DOORS
À "OFF". SITUÉ
CERTIFIED WITH THIS UNIT ONLY.
WARNING
:
DO NOT ADD ANY MATERIAL TO
HD81NT
THE APPLIANCE, WHICH WILL COME IN
0-4500FT (0-1370M)
CONTACT WITH THE FLAMES, OTHER THAN
60,000 BTU/H
À "ON".
THAT SUPPLIED BY THE MANUFACTURER
22,000 BTU/H
WITH THE APPLIANCE.
MINIMUM CLEARANCE TO COMBUSTIBLE
MANIFOLD PRESSURE: 3.5" WATER COLUMN
MATERIALS:
PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU
TOP
0
RECESSED DEPTH 25"
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
FLOOR
0
VENT
2"
PRESSION D'ALIMENTATION MINIMALE: 4.5" D'UNE COLONNE D'EAU
SIDES
0
MANTEL
16" *
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
BACK
0
PRESSION D'ALIMENTATION MAXIMALE: 7.0" D'UNE COLONNE D'EAU
TOP, SIDES & BACK: PER STAND OFF SPACERS FOR
FRAMING MATERIALS. FOR FINISHING MATERIALS
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE
SEE OWNERS MANUAL
NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL
* MAXIMUM HORIZONTAL EXTENSION: 2"
FOR VENTING SPECIFICS. PROPER REINSTALLATION AND
G SPECIFICS. PROPER REINST
SEE INSTRUCTION MANUAL FOR GREATER EXTENSIONS.
RESEALING IS NECESSARY AFTER SERVICING THE VENT-AIR
S NECESSARY AFTER SER
SEE OWNER'S INSTRUCTION MANUAL FOR MINIMUM
AND MAXIMUM VENT LENGTHS.
ELECTRICAL RATING: 115V 0.82AMP, 60HZ
SERIAL N
SERIAL NUMBER/NO. DE SÉRIE:
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE. ONTARIO L4M 0G8 CANADA
65%
HD81
RATING
PLATE
AREIL D
FOYER DE CHAUFFAGE AU GAZ AVEC ÉVACUATION. HOMOLOGUÉ POUR INSTALLATION DANS UNE CHAMBRE À
HAUFFAGE A
COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIÉ POUR INSTALLATION DANS UNE MAISON MOBILE SI
UNE SALLE DE
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SÉRIE DE MAISONS MOBILES
TALLATION CONFORME
ÉQUIPÉES AU GAZ, EN VIGUEUR AU CANADA OU AUX ÉTATS-UNIS DE LA NORME DE SECURITÉ ET DE CONSTRUC-
ES AU GAZ, EN VIGUEUR A
TION DE MAISONS MANUFACTURÉES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME D'ÉTATS-UNIS
AISONS MANUFACTURÉ
NE PEUT ÊTRE APPLIQUÉE, SE RÉFÉRER A LA NORME RELATIVE AU CRITÈRE DE MESURES DE SÉCURITÉ CONTRE
E APPLIQUÉE, SE
L'INCENDIE POUR LES INSTALLATIONS DANS LES MAISONS MANUFACTURÉS, LES SITES ET LES COMMUNAUTÉS,
L'INCENDIE POUR LES INSTA
ANSI/NFPA 501A.
ANSI/NFPA 501A.
UN COMBUSTIBLE SOLIDE NE DOIT
PAS ÊTRÉ UTILISÉ AVEC CET
9700539 (WSL)
4001657 (NGZ)
4001657 (NGZ)
APPAREIL. UTILISER AVEC LES
4001658 (NAC)
4001659 (WUSA)
4001659 (WU
PORTES VITRÉES HOMOLOGUÉES
HD81PT
MODEL/MODÈLE
DEL/MODÈLE
SEULEMENT AVEC CETTE UNITÉ.
ALTITUDE / ÉLÉVATION
TUDE / ÉLÉVATIO
0-4500FT (0-1370M)
AVERTISSEMENT:
INPUT / ALIMENTATION
PUT / ALIMENTAT
50,000 BTU/H
REDUCED INPUT / ALIMENTATION RÉDUITE
INPUT / ALIMENTATIO
16,000 BTU/H
APPAREIL AUCUN MATÉRIAU DEVANT ENTRER
EN CONTACT AVEC LES FLAMMES AUTRE QUE
5" WATER COLUMN
MANIFOLD PRESSURE: 10" WATER COLUMN
AN
CELUI QUI EST FOURNI AVEC CET APPAREIL
UNE COLONNE D'EAU
PRESSION AU COLLECTEUR: 10" D'UNE COLONNE D'EAU
P
PAR LE FABRICANT.
E: 4.5" WATER COLUM
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
DÉGAGEMENTS MINIMAUX DES MATÉRIAUX
UNE COLONNE D'EAU
PRESSION D'ALIMENTATION MINIMALE: 11" D'UNE COLONNE D'EAU
COMBUSTIBLES:
0" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
DESSUS
0
PROFONDEUR D'ENCASTRÉ 25"
ALE: 7.0" D'UNE COLONNE D'EA
PRESSION D'ALIMENTATION MAXIMALE: 13" D'UNE COLONNE D'EAU
PLANCHER 0
ÉVENT
AFUE
AFUE: 65%
AFUE: 68%
CÔTES
0
MANTEAU
ARRIÉRE
0
ENTED USING THE APP
L'APPAREIL DOIT ÉVACUER SES GAZ EN UTILISANT L'ENSEMBLE
DESSUS, COTÉS & ARRIÈRE: SELON LES ESPACEURS
OWNERS INSTALLATI
D'ÉVACUATION PROPRE A NAPOLEON. RÉFÉRER AU MANUEL
D'INSTALLATION DE PROPRIÉTAIRE POUR L'ÉVACUATION
DE DÉGAGEMENT POUR LES MATÉRIAUX D'OSSATURE
PRÉCISE. IL EST IMPORTANT DE BIEN RÉINSTALLER ET
SELON LE MANUEL DE PROPRIÉTAIRE POUR LES
INTAKE SYSTEM.
RESCELLER L'ÉVENT APRÈS AVOIR ASSURÉ LE MAINTIEN DU
MATÉRIAUX DE FINITION.
* L'EXTENSION HORIZONTALE MAXIMALE: 2". RÉFÉRER
SYSTÉME DE PRISE D'AIR.
AU MANUEL D'INSTRUCTION POUR DES EXTENSIONS
PLUS GRANDES. RÉFÉRER AU MANUEL D'INSTALLATION
DE PROPRIÉTAIRE.
HD81
CLASSIFICATION: 115V 0.82AMP, 60HZ
W415-0687 / G / 08.26.13