Testing the effectiveness of the
vacuum cleaner
NOTE:
In addition, the effectiveness of the
vacuum cleaner class H must be che-
cked at least once a year.
There must be an adequate air exch-
ange rate L in the room if the exhaust
air returns to the room. Further infor-
mation can be taken from your natio-
nal regulations.
If the suction of the vacuum cleaner
reduces and the cleaning procedure of
the folding filter cassettes increases,
the suction performance is not ade-
quate (provided that the container is
empty and the fleece filter bag has
been replaced) then it is necessary to
replace the folding filter cassettes.

10. First aid in the event of a fault

NOTE
Malfunctions cannot always be traced back to defects in the vacuum cleaner.
Fault
Reduction in suction
Vacuum cleaner will
not start
Translation of the original instruction
9.1 Cleaning
NOTE
Acids, alkalis and solvents can corro-
de the vacuum cleaner parts.
Clean the container and accessories
with water.
Wipe the top section with a damp clo-
th.
Allow the container and accessories
to dry.
9.2 Repair
DANGER
Inappropriately repaired vacuum clea-
ners present a danger to the operator.
Have repairs carried out by specia-
lists, e. g. customer service.
Use only genuine spare parts.
Possible cause
Filter contaminated
Fleece filter full
Container full
Nozzle, pipes or hose blo-
cked
Mains plug plugged in?
Mains power missing?
Mains cable OK?
Cover closed properly?
Water sensor switched off?
Vacuum cleaner in readiness
for operation
96
Remedy
Clean
Change
Empty
Clean
Set to >I< (see „1 Dis-
play and Operating
Elements").