- GB -
Safe operation
• Never operate the unit if either the electrical cables or the housing are defective!
• Do not carry or pull the unit by its electrical cable.
• Route cords/hoses/lines in a way that they are protected against damage, and ensure that they do not present a
tripping obstacle.
• Only open the unit housing or its attendant components, when this is explicitly required in the operating instructions.
• Only execute work on the unit that is described in this manual. If problems cannot be overcome, please contact an
authorised customer service point or, when in doubt, the manufacturer.
• Only use original spare parts and accessories for the unit.
• Never carry out technical modifications to the unit.
• The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
• Only operate the unit if no persons are in the water!
• Keep the socket and power plug dry.
Installation
When delivered, all components to be assembled are in the filter container and have to be removed first!
Opening/ closing the container
9.
How to proceed:
0.
B
Opening the container
• Carefully push the lugs located at the container side away from the detent tabs, then lift off the container lid.
Closing the container
• Place the container lid onto the container and carefully press down until the lugs engage over the detent tabs. (Not
shown.)
Fit filter
1.
How to proceed:
0.
C
1. Take kit, hose and submersion unit out of the container and place aside.
2. Insert the inlet bend through the inlet opening, then align with the container bottom.
3. Screw a hose connector from the kit on to the inlet bend at the outside of the container.
− The union nut of the hose connector must have an O ring. Insert, if necessary.
4. Close the container. (→ Installation)
Connect the submersion unit to the filter
5.
How to proceed:
0.
1. Screw a hose connector from the kit on to the outlet of the submersion unit.
2. Push the hose ends up to the hose connector stop of both units.

Installation and connection

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
• Prior to reaching into the water, disconnect the power supply to all units used in the water.
• Disconnect the power plug prior to carrying out work on the unit.
3.
How to proceed:
0.
D, E
1. Place the submersion unit on level ground in the pond, and install the filter at the pond bank.
− Note the maximum submersion depth of the submersion unit.
− The filter can stand freely or can be buried up to half of its height as a maximum.
− Recommendation: The filter outlet points to the pond.
2. Return the water into the pond and ensure a sufficient hose gradient.
− A DN 50 HT tube system or 2" hoses can be used to return the water into the pond.
− On the unit side, the tube is pushed into the outlet or the 2" hose is fastened to the outlet using a hose clip.
3. Prepare the electrical connection.
− Route the connection tubes/hoses safely. (→ Safety information)
14
21580-08-13_GA_PondoClear Set 4014 14
22.08.2013 17:00:56

Publicité