Accessories; Troubleshooting; Fault Handling; Maintenance And Repairs - DOLD UH 5947 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Accessories

OA5947/100:
KY5947 H1/S1:
KY5947 H2/S4:

Troubleshooting

Failure
LED "SF" ON
LED "Device" ON red
LED "Device" flashes red

Fault Handling

When faults are detected on or in the device they are indicated on the
display by an appropriate message. If a reset of the device is necessary
due to the fault, at first the alarm and the associated diagnostic message
have to be acknowledged. Then, the left key has to be pressed for approx.
3 sec. to initiate a reset of the device.
Automatic operation
80 - 100 m/min
Standstill
< 10 m/min
R
ü
If a system failure is detected again after restart the device must be re-
placed and sent back to manufacturer.

Maintenance and Repairs

- The device contains no parts that require maintenance.
- In case of failure, do not open the device but send it to manufacturer for repair.
Connection cable for copy function and
adaptor
15 pole adaptor to connect an encoder or
for controllers of Siemens /Heidenhain with
corresponding PIN arrangement
(see remarks for accessories in operating
manual)
25 pole adaptor to connect an encoder or
for controllers of Siemens /Heidenhain with
corresponding PIN arrangement
(see remarks for accessories in operating
manual)
Potential cause
- external failure
(detailed description on display)
- Device failure
(if the failure still exists after restart,
replace device)
- Parameter failure
(min. one adjusted frequency to be
monitored is out of range)
M10374

Characteristics

2
2
I (A )
100
80
60
40
20
0
0
10
20
30
40
50
60
Max. zulässiger Strom bei 60°C über
^
4 Kontaktreihen = 2A = 4x2 A = 16A
2 2
2
2
2
2
2
I = I + I
I + I
+
1
2
3
4
I , I ,
I , I
- Strom in den Kontaktpfaden
1
2
3
4
quadratic total current limit curve
29
2
16 A
°
T ( C)
M10484
2
UH 5947 / 10.01.17 en / 813