Technical Data; Ordering Designation; Variants And Accessories; Safety Related Data - DOLD SAFEMASTER STS 01 Traduction De La Notice Originale

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Data

Mechanical Data
Enclosure:
General Data
Temperature range:
Storage range:
Variante:
Coding level high according to DIN EN ISO 14119:2014-03

Ordering Designation

Key module 01
Article number: 0061871
Key module 10
Article number: 0061870
Key module 01S
Article number: 0063372
Key module 10S
Article number: 0063373
Key module R1
Article number: 0062930

Variants and Accessories

Key modules with protective cover
The key modules can be alternatively equipped with a protective cover.
It is located in the key insertion opening. When the key is pulled out it
offers protection from penetrating dirt like sand and dust. Since the
SAFEMASTER STS for key coding works with a coding barrel and not
with delicate pins, this protective cover together with the lateral cleaning
holes is sufficient as protective measure against most of the dirt. The
protective cover offers only limited protection against the penetration of
fluids.
The key modules with protective covers receive an additional "S" at the
end of their normal type designation. Therefore, their full designation is
01S or 10S.
Examples of devices with protective cover:
M10SA, M11SBM, SX02SM.
Special design R1 module
This module functions like key module 01, the key is not fixed in its
position when inserted but is ejected again with spring force.
This module is used, for example, in inching mode.
Example for a unit with ejection spring:
SXR1.
Stainless steel VA4 / AISI 316L
- 40°C to + 100°C
- 40°C to + 100°C
• Key module 01:
Removal of the key to release the upper
module and lock the lower module
• Key module 10:
Inserting the key to release the upper
module and lock the lower module

Safety Related Data

Data suitable for the PFH
summation method according to
d
EN ISO13849-1:2016
Data
according
to EN
ISO13849-
1:2016
Category
2
PL
d
PFH
1,061E-09
6,84592E-10 5,44569E-10 1,00122E-10
d
T
20
10d
CCF
65-100
required
B
2.000.000
10d
d
(d/a)
365
op
h
(h/d)
24
op
t
(h)
1
cycle
n
8760
op
Diagnostic
60%
coverage DC
Test interval
according to
1 / year
ISO14119
Category 2: The prerequisites for installation and integration into a
category 2 architecture must be met
Category 3: The prerequisites for installation and integration into a
category 3 architecture must be met
Category 4: The prerequisites for installation and integration into a
category 4 architecture must be met, in particular 2
actuators must be used
PFH
:
A single module has no function. As a result, an individual
d
module cannot have any safety-related characteristic values.
The safety-related characteristic data in the table only serve
to determine the values of a unit into which it is integrated.
When used as part of a key transfer system:
- PFH
total STS system = SUM PFH
d
- Lowest category of a module = category of whole
STS system
- Lowest DC of a module = DC entire STS unit
!
If the design of a unit is changed, the safety-related data may also
change.
10
SAFEMASTER STS Key modules 01 and 10 / 09.07.20 en / 267A
Key modules 01 and 10
3
3
d
e
20
20
85-100
85-100
2.000.000
2.000.000
2.000.000
365
365
24
24
1
1
8760
8760
60%
90%
1 / year
1 / month
1 / month
+ ... PFH
d1
4
e
20
85-100
365
24
1
8760
99%
dn

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Safemaster sts 10