If the condition persists, remove the Cell from the Vessel and check that the flow switch is free to
move in both directions. Refer to the diagram below.
5.
CELL LIFE LOW LED illuminated
The Cell has reached the end of its life. Replace as soon as possible.
6.
PROBLEM DETECTED LED illuminated AND MAX LED blinking
There is a communication error with the Cell. Check that the Cell cap is properly plugged in and
that the wire to the Control Box is not cut or damaged.
7.
PROBLEM DETECTED LED illuminated AND MIN LED blinking
•
The salt level may be too low. Adjust salt to recommended levels.
•
Remove and inspect the Cell for scale. If the Cell is scaled, follow the directions on page 14
for Cell cleaning.
8.
PROBLEM DETECTED LED illuminated AND a DAILY CHLORINE OUTPUT LED is
blinking
The Salt & Swim may display an error by illuminating the PROBLEM DETECTED LED and blinking
one of the DAILY CHLORINE OUTPUT LEDs. There are ten DAILY CHLORINE OUTPUT LEDs that
each indicate a different error. These LEDs are labeled with a number on the diagram below.
Refer to the table for their corresponding errors.
16
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Flow Switch
4
3
2
1
10
9
8
7
6
5