Bonding
A lug used for bonding is attached to the bottom of the Aqua Trol enclosure. Connect to the pool
bonding system using minimum 6AWG copper wire if required by code.
Electrolytic Cell
Route the cell cable through the enclosure cutout and connect to the Aqua Trol.
Cutout for
cell cable
INPUT POWER
Bonding lug to
120 VAC linecord
pool bonding system
to GFCI receptacle/breaker

Operation

Controls
The pool filter pump should run long enough to circulate the entire volume of pool water each day.
This will vary depending on pump size, pool plumbing and pool size. Consult a local pool store to
help determine the appropriate run time for your pool.

Main Switch

AUTO: For normal operation, the Main Switch should be left in the AUTO position. In this position
the Aqua Trol will produce chlorine according to the "Desired Output %" adjustment setting for the
entire filtering/pumping cycle.
SUPER CHLORINATE: When you have an abnormally high bather load, a large amount of rain,
a cloudy water condition, or any other condition which needs a large amount of purification to be
introduced, put the Main Switch in the SUPER CHLORINATE position. This electronically "super chlo-
rinates" (shocks) the water for 24 hours (filter pump must be on during this time) or until the power
has been turned off, whichever comes first. At the end of the super chlorinate time, be sure to put
the switch back into the AUTO position.
OFF: The OFF position prevents the Aqua Trol from energizing the electrolytic cell. In this position
there is no chlorine generation. NOTE: To service any of the pool equipment or the Aqua Trol, turn
the power off at the circuit breaker.
8
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS