Preparing Pool Water
To prepare the pool water for Salt & Swim operation, the pool's chemistry must be balanced and
salt must be added. This must be done BEFORE activating the Salt & Swim. Some adjustments to
your pool chemistry may take several hours, so start the procedure well before you intend to operate
the Salt and Swim.
To prepare your pool water, follow the instructions on the included Pool Chemistry Quick Start Guide
and refer to page 8 of this manual.
Adding Salt: Add salt several hours or, if possible, 1 day prior to operating the Salt & Swim . Take
care not to exceed the recommended salt level. Measure salt 6-8 hours after adding to the pool.
NOTE: If the pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter)
of non-copper based algaecide to the pool, per manufacturer's instructions. This ensures a quick,
troublefree transfer to the Salt & Swim system.
Mounting the Salt & Swim
Control Box
The Salt & Swim is contained in a
raintight enclosure that is suitable for
outdoor mounting. The Control Box
uses a 3 ft linecord that must plug
into a GFCI protected outlet. The Cell
must be installed within 15 ft of the
Control Box using the attached cable.
The Control Box is designed to mount
vertically on a flat surface with the
cables facing downward. Because
the enclosure also acts as a heat
sink (disperses heat from inside the
box), it is important not to block the
four sides of the Control Box. Do not
mount Salt & Swim inside a panel or
tightly enclosed area.
Before securing the Control Box to the
intended location, make sure that the
power cord will reach the GFCI pro-
tected outlet and that the Cell cable
will reach the location where the Cell
Vessel will be installed. Refer to the
diagram below.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Screw in top
fasteners leaving
1/8" space between
screw head and surface
Screw in bottom fasteners securely.
Hang Control
on fasteners
3