Stove phase general layout

Phase
FINAL CLEANING
SWITCH ON
WAITING FOR FLAME
FLAME PHASE
WORK AT MAX P
WORK AT MIN P
WORK AT DHW P
MODULATE H2O
ROOM TEMPERATURE
MODULATION
THE GRATE
ECO STOP
START/RESTART WAIT
SWITCH ON RESTART
HOT SMOKE
Use and maintenance manual Touch Radio Hydro
Description
The stove is in the switch off phase and the cooling phase has not been completed
yet.
The heater pre-heating phase has started and the pellets start to fall into the grate.
The pellets ignite and take advantage of the heat in the intake air that passes through
the incandescent heater tube.
The flame develops in the
The stove has completed the switch on phase and runs at maximum set power
The stove works at the operating power set after ignition.
The stove works at an operating capacity dedicated to DHW
(flow switch request with DHW kit or DHW boiler)
The desired boiler water set temperature has been reached.
The room temperature set has been reached.
Brazier cleaning phase is active (periodic function).
With Climate Comfort active, the stove switches to automatic switch-off mode when
the room temperature set is reached (see the dedicated section).
Switch-on is requested but with the stove in cooling phase; once this condition is
met, it restarts automatically.
The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
The maximum fume temperature threshold has been reached. To facilitate cooling,
the stove brings the capacity to a minimum with ventilation at power level 5, leading
to a decrease in fume temperature.
grate.