Hydraulic diagrams
With this thermo-stove, different types of system can be handled - both those where thermo-stoves are directly connected to heating
circuits, and more complex systems with accumulators (Boilers, Buffer tanks or both) for DHW production. The hydraulic diagram to
be used must be chosen via the display by an authorised technician when the thermo-stove is installed.
Diagram 0 (heating system only)
In this type of circuit, the stove is directly connected to the heating system. This is the default set diagram.
LEGEND
Stufa a Pellet
1- Pellet stove
2- Distribution manifolds
3- Radiators
4- Thermometer
5- Pressure gauge
6- Anti-condensation valve
The diagram shown here is indicative and may not display all the components required to properly operate the system. Rely on a
qualified thermal technician for the hydraulic system design.
NOTE: The DHW KIT can also be used in this diagram
Use and maintenance manual Touch Radio Hydro
7- Check valve
8- Group of direct distribution
9- Thermostatic distribution unit
10- Radiant panel (underfloor heating)
11- Shut-off valve
12- Thermostat
13- Power separation system
14- Gas boiler
Rev.0 18/05/2021
EN
Pag.25