Warning Pop -Up
Anomaly
RDS SYSTEM REGULATION
ADJUST
REQUEST
RDS
(only if the RDS system is
SYSTEM
installed)
FLOW METER FAILURE
(only if the RDS system is
installed)
SERVICE REQUEST
Signalling
CLEAN THE GRATE
(only if the RDS sys-
tem is installed)
��
The appearance of the "SET RDS" message indicates that the initial parameter testing and calibration procedure was not
carried out correctly. This indication does not imply blocking the stove.
Use and maintenance manual Touch Radio Hydro
Description
It shows that the testing procedure and initial parameter calibration have been
completed incorrectly.
This indication, however, does not block the stove.
It shows a failure of the air flow meter and the stove switches to minimum ca-
pacity disabling the RDS system.
The threshold value of set work hours has been reached. The symbol
displayed remains active throughout the work phase. Non-routine maintenance
is required on the stove.
Reason
The door and the ash box are not
closed correctly
Poor combustion in grate.
Presence of foreign body in air in-
take tube.
The air flow meter may be dirty.
Solution
Make sure they are closed properly.
Switch off the stove, clean the brazier and check the cleanliness of
the support bench, clean the tube bundle by activating the turbolators
and adjust the combustion through pellet/air settings.
Check if present and remove foreign body
Clean the flow meter with the stove in "Switched off" state
Contact the Support Service