The other end of the conduit can be connected to a user-supplied junction
box or directly to a transmitter.
If the conduit is connected to a user-supplied junction box, connect the
wires to the terminals on the junction box. If possible, install wiring
with junction box openings pointed down, or with drip legs in the
conduit, to reduce the risk of condensation or excessive moisture in
the junction box. Next, connect the 9-wire cable from the junction box
to the transmitter by following the instructions in 9-wire cable wiring.
If the conduit is connected directly to a transmitter, refer to the wiring
instructions in the transmitter Quick Reference Guide.
Figure 10. Model DT sensor wiring
1/2" NPT conduit
3 ft. (1 m) factory-supplied flex conduit
Liquid tight to meet CE requirements
for European installations
fitting
Grounding screw
User-supplied
junction box
14
Drip leg