Installing/Replacing Cleaner Or Sanitizer Bottles; Changing The Solution Type - Manitowoc iAuCS Manuel D'installation, D'utilisation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section 3
Installing/Replacing Cleaner or Sanitizer
Bottles
! Caution
Do not mix Cleaner and Sanitizer solutions together.
It is a violation of Federal law to use these solutions
in a manner inconsistent with their labeling.
1. Remove left panel.
2. Unscrew nozzle/tubing from bottle, then remove
bottle.
3. Remove bottle cap and foil seal from new bottle.
4. Install nozzle/tubing on new bottle.
5. Reinstall left panel.
Unscrew cap and remove bottle
Remove cap and foil seal from
new bottle and install
Part Number 000009036 8/13

Changing the Solution Type

! Caution
Wear rubber gloves and safety goggles (and/or face
shield) when handling Cleaner and Sanitizer.
! Caution
Do not mix Cleaner and Sanitizer solutions together.
It is a violation of Federal law to use these solutions
in a manner inconsistent with their labeling.
!
Do not use 1 gallon bottles of Cleaner or Sanitizer
on the AuCS® accessory.
Use the following procedure to flush the system prior to
changing from Cleaner to Sanitizer or from Sanitizer to
Cleaner.
1. Remove the bottle of Cleaner or Sanitizer from the
AuCS®. Flush the bottle thoroughly then fill with
water.
2. Repeat the following until the water bottle is empty
(approximately 8 times):
A. Press the CLEAN button.
B. The water pump and dump valve will turn on.
The dump valve will shut off after approximately
45 seconds.
C. The control waits until the water contacts the
water level probe then energizes the AuCS®
pump (22" or 30" ice machines - 30 seconds,
48" ice machines - 60 seconds).
D. Press the POWER button after step C is
completed.
3. Install a new bottle of cleaner or sanitizer solution.
Operation