10-576
7.2. Error detection and indication
Errors are visually and acoustically signalled: error signal sounds and both LEDS keep flashing.
Cause
a- and P-conductors are switched
or short circuited
a- or M-conductor not connected
or without power supply
key is locked
(pressed for longer than 15 s)
8. SETTINGS

8.1. Factory settings

Image connection depends on BP address
In installations with 10-576, in which both external video units and external audio units are installed, the image of the external audio units is not activated during
a call. In view of this function, the possible BP addresses are divided in two parts:
ExtU address 0 – 31*
ExtU address free as of 32*
8.2. Preset times
Speaking time
Remaining speaking time after touching door opener
Display time
Flashing time of the green LED if video / audio channel is assigned upon touching the
speech key or image key
Internal standby time
Floor door opening time
Time-out OSD menu
Time-out OSD integration in the video image
9. CONFIGURATION

9.1. Configuration options

Function
Fixed simplex conversation mode
Simplex conversation mode with external unit
Ring tone volume
Ringtones for doorcalls, sub-doorcalls, internal calls and floor calls
Call diversion
Ring-and-come-in
Internal call
Control function 8
Restore switching lights on/off
Parallel assignment
Floor door opening function on / off
Automatic hands-free conversation after internal call on / off
70
Indication in error mode
both LEDs are flashing.
restricted to external video units
for external units without camera
Error signal
Solution
switch the a- and P-conductor or resolve the short circuit;
device will return to standby
check a- or M-conductor connection or power supply, device
will return to standby
release key on 10-576 or floor key, device will return to
standby
image is activated upon door call (of max. 16 external video units)
image is not activated upon door call
2 min.
4 sec.
80 sec.
flashes 3 x 6 sec.
approx. 30 sec.
approx. 30 sec.
10 sec.