6.4. Wiring diagram

floor key
floor key
8-24 V
1 3
230 V/50 Hz
Door opener
7. INITIAL ACTIVATION
WARNING! Fatal electric shock.
Please observe the safety requirements in accordance with generally applicable laws, standards, rules and regulations.
• Ensure the installation is completely connected. Mount all components.
• In turn, check a-, b- and P-conductor against each other for short circuits.
• Switch on the mains voltage.
7.1. Connecting floor key
• Connect the floor key to the E- and P-conductors.
It also possible to connect the floor key to the a- and E-conductors.
Ensure that the a-wire of the power supply and control unit is connected to the a-conductor of the internal unit.
EN
a b E P M C V1 V2
a b E P M C V1 V2
Light
14
15
16
17
24 23 25
a
b P
> 6 Ω
Image 9: Example of a wiring diagram
6-wire technique
29 31
+
230 V/50 Hz
R
P
M
V1 V2
a b
Important:
Set the terminal resistor, when the
device is installed at the end of a
bus video line.
Internal video
unit 10-576
Internal video
unit10-576
L
N
5 7
9
10-576
10-801
10-805-01
External unit
10-404
69