Ribimex PRGES2000I Mode D'emploi page 42

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.5- Charging battery (Fig. 20)
Fig. 20
1. Disconnect the ground wire from the vehicle battery from the negative (-) terminal.
2. Connect the battery charging cable (1) to the 12VDC socket (2) of the generator.
3. Connect the red clamp of the charger (4) to the positive terminal of the battery (+) and the black
clamp (5) to the negative (-) terminal.
4. Set the ECO switch (3) to the OFF position.
5. Start the generator motor.
6. Battery charging time varies by model, DC breaker (6) does not prevent overcharging of the
battery.
WARNING :
The 12VDC socket should only be used for 12V batteries.
Always set the ECO switch to the OFF position.
Never reverse polarity.
Never start a vehicle while charging the battery.
Overcurrent of the DC circuit or a wiring problem will trip the DC circuit breaker (spring
push button). If necessary, wait a few minutes before resetting.
Disconnecting the battery charging cable:
1. Place the engine switch in the OFF position to stop the engine.
2. Disconnect the black clamp from the charger from the negative terminal of the battery.
3. Disconnect the red clamp from the charger from the positive terminal of the battery.
4. Remove the battery charging cable from the 12VDC socket of the generator.
5. Connect the vehicle ground wire to the negative terminal of the battery.
4.6- Using the "Gen-mate" application
4.6.1- Downloading and Connection
1. For both IOS and Android systems, download the "Gen-mate" application and install it according
to the instructions.
2. Click on "Free Register" and then enter the required data to complete the installation:
- 39 -