9. Set the ECO switch (black) to the ON position (Fig. 15).
9. Connect the plug to the AC socket for electrical devices (Fig. 16).
10. Turn on your electrical appliance.
Make sure electrical appliances are turned off before connecting them to the
generator.
Notes :
1. The ECO Switch 1 must be turned to OFF position when using electric devices that require
a large starting current, such as a heavy compressor or some high electrical loads.
2. Be sure all electrical devices including the lines and plug connections are in good condition
before connecting them to the generator.
3. Be sure the total load is within generator rated output.
4. Be sure the receptacle load current is within receptacle rated current.
5. If the generator is overloaded (in excess of rated power), or if there is a short circuit in a
connected appliance, the OVERLOAD LED (red) will light on, and the current to the
connected appliance(s) will shut off, and the READY LED (green) will light off.
6. The Reset Button 3 can be used to recover output of the generator under the condition of
overload protection, and unnecessary to restart engine overall. But at first check and correct
the problem, if there is a short circuit in a
7. When an electric motor is started, the OVERLOAD LED (red) may light on. This is
normal if the OVERLOAD LED (red) will light off after a few seconds.
Fig. 15
Fig. 16
connected appliance or wire.