Minimum Combustible Mantel Clearances - Napoleon HIGH COUNTRY 5000 Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

framing
EN
5.4

minimum combustible mantel clearances

WARNING
!
Risk of fire. Maintain all specified air space clearances to combustibles. Failure to comply with these instructions
may cause a fire or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,
front, etc.) are clearly maintained.
When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.
When installing an unvented gas log set, all minimum clearances must be adhered to.
If the mantel is installed to cord wood clearances, an unvented gas log set cannot be installed.
See chart below for further information on mantel installation. Do not exceed the specified mantel depths or
minimum mantel heights outlined.
Clearances for burning cord wood & vented gas
Maximum mantel depth vs. mantel height
24
W415-1720 / G / 05.14.21
logs
A = 12" (30.5cm)
B = 8" (203mm)
C = 4½" (114mm)
D = ¾" (19mm)
A
B
C
E = 5½" (140mm)
D
F = 7½" (191mm)
G = 9½" (241mm)
H = 11½" (292mm)
E
F
G
H
Faceplate
31 9/16"
(80.2cm)
Clearances for unvented gas log set
*maximum 12" mantel depth at any height above
28 7/16" (72.2cm) from the top of the faceplate.
A = 12" (30.5cm)*
A
28 7/16"
(72.2cm)
Faceplate