installation planning
EN
3.6
flue damper operation
To close the flue damper, pull the damper control rod down and
push it to the right.
To open the damper, pull down slightly and push the damper con-
trol rod to the left side and release.
note:
The damper must be in the "open" position when burning.
note:
If the damper becomes unthreaded, it will remain in the "open" position.
note:
If the damper does not operate properly, do not proceed with chimney installation. The damper operation
should be thoroughly checked before the chimney is installed.
14
W415-1720 / G / 05.14.21
OPEN
CLOSED
OPEN
OPEN
CLOSED
CLOSED