WARNING
!
Never install a single wall slip section or smoke pipe in a chase structure. The higher temperature of this
single wall pipe may radiate sufficient heat to combustible chase materials to cause a fire.
To avoid danger of fire, all instructions must be strictly followed, including the provision of air space
clearance between chimney system and enclosure. To protect against the effects of corrosion on those
parts exposed to the weather.
Maintain a minimum 2" (51mm) air clearance to all parts of the chimney system at all times. Failure to
maintain this 2" (51mm) air clearance will cause a structure fire.
Detailed instructions for installation of the storm collar and termination cap are packaged with these parts.
Firestop spacers must be used whenever the chimney penetrates a ceiling/floor area.
The chimney must be sound and free of cracks. Clean your chimney a minimum of twice a year and as
required.
Always seal penetrations with temperature rated sealing products.
Installation of a combustible chase enclosure above the roof is permissible if done in accordance with the
chimney manufacturer's installation instructions.
4.1

chimney

note:
All venting connections must be in compliance with the chimney manufacturer's installation instructions.
This appliance was tested to CAN/ULC S610 and UL 127 Factory Built Fireplace Standards. This appliance has
met the test criteria for Zero Clearance Installation to Combustible Surfaces and Certified to burn firewood only.
Any chimney 8" (203mm) in diameter certified on an appliance listed to CAN/ULC S610 for Canada or UL127 for
the United States or to the following standards; CAN/ULC-S604 and CAN/ULC-S629 for Canada or UL-103 or
UL-103HT for the United States may be installed.
Installation of all types of factory-built chimney systems is to be in accordance with the chimney manufacturer's
installation instructions. An appropriate chimney manufacturer's anchor base plate and anchor base plate gasket
is required in order to initiate their system. Use the high temperature gasket, supplied, to seal between the anchor
plate and the appliance top. Air cooled chimney
systems are not recommended in colder climates.
For complete installation instructions, refer to
instructions provided with the manufactured chimney
system.
A chimney venting the appliance shall not vent any
other appliance. The minimum overall chimney height
from the top of the appliance is 15ft (4.6m). The
maximum overall chimney height from the top of the
appliance is 34ft (10.4m).
Factory-built chimney systems for use in dwellings
constructed for three or more families must be
enclosed above the room in which the appliance is
located. This enclosure must have a fire resistance rating equal to or greater than that of the floor or roof
assembly through which they pass.
The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA. Ensure that
minimum clearances are maintained.
Portions of the chimney that extend through accessible spaces must always be encased to avoid personal
contact with the chimney and thereby avoid damage to the chimney.
The chimney must be supported at a maximum of 20ft (6.1m) intervals. Every 20 ft (6.1m) of chimney can weigh
up to approximately 200lbs (90.7kg). Refer to chimney manufacturer's specifications.
When using an 8" chimney, carefully center the anchor plate to the appliance flue outlet. Ensure the anchor plate
flange and gasket completely cover the flue outlet.
note:
When installing insulated chimney with an anchor plate smaller than 12" (30.5cm) x 12" (30.5cm), an AP8 kit
must be installed (securing plate).
note:
Masonry chimney installs are not permitted.
note:
Gasket supplied must suit chimney anchor plate or use chimney supplier's gasket.
(Optional AP8 kit
componants)
Insulated chimney configuration illustrated.

4.0 installation

installation
Anchor plate (chimney
specific*)
Anchor plate gasket 8"
Securing plate
Securing plate gasket 10"
Appliance top
Anchor plate* for a
factory built chimney
W415-1720 / G / 05.14.21
EN
15