5 OPERATION
5.9
Duty cycle
The EMP235ic and EM235ic both have a welding current output of 235 A at 40% duty cycle
(230 V). A self-resetting thermostat will protect the power source if the duty cycle is
exceeded.
Example: If the power source operates at a 40% duty cycle, it will provide the rated
amperage for a maximum of 4 minutes out of every 10 minute period. The remaining time,
6 minutes, the power source must be allowed to cool down.
4 minutes
A different combination of duty cycle and welding current can be selected. Use the graphs
below to determine the correct duty cycle for a given welding current.
0463 479 001
6 minutes
Duty cycle on 120 V AC
Welding current (AMPS)
- 27 -
© ESAB AB 2017