4 INSTALLATION
Setting range (DC)
Open circuit voltage (OCV)
VRD deactivated
VRD activated
Efficiency
Power factor
Wire feed speed
Wire diameter
Mild steel solid wire
Stainless steel solid wire
Flux cored wire
Aluminum
Bobbin size
Dimensions l×w×h
Weight
Operating temperature
Enclosure class
Application classification
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld at
a certain current without overheating. The duty cycle is valid for 104 °F / 40 °C.
For more information, see section "Duty cycle" in the OPERATION chapter.
Enclosure class
The IP code indicates the enclosure class, i.e. the degree of protection against penetration
by solid objects or water.
Equipment marked IP 23S is intended for indoor and outdoor use; however, should not be
operated in precipitation.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
4
INSTALLATION
The installation must be carried out by a professional.
CAUTION!
This product is intended for industrial use. In a domestic environment, this
product may cause radio interference. It is the user's responsibility to take
adequate precautions.
0463 479 001
15 A / 14.75 V – 250 A / 30.0
V
68 V
35 V
84%
0.98
60-700 in./min
(1.5-17.89 m/min)
0.023–0.045 in. (0.6–1.2 mm) 0.023–0.045 in. (0.6–1.2 mm)
0.030–0.045 in. (0.8–1.2 mm) 0.030–0.045 in. (0.8–1.2 mm)
0.030-0.052 in. (0.8-1.3 mm)
0.030–0.045 in. (0.8–1.2 mm) 0.030–0.045 in. (0.8–1.2 mm)
Ø 4–12 in. (100–300 mm)
23 × 9 × 16 in.
(548 × 229 × 406 mm)
53 lbs (24 kg)
-14 to +104 °F (-10 to +40 °C) -14 to +104 °F (-10 to +40 °C)
IP23S
- 15 -
EM235ic
15 A / 14.75 V – 130 A / 20.5
V
68 V
35 V
84%
0.99
60-700 in./min
(1.5-17.89 m/min)
0.030-0.052 in. (0.8-1.3 mm)
Ø 4–12 in. (100–300 mm)
23 × 9 × 16 in.
(548 × 229 × 406 mm)
53 lbs (24 kg)
IP23S
© ESAB AB 2017