Ref. Description
1
Box
2
Gear motor K10
3
Winding shaft
4
Transmission chain
5
Counterweight belt drum
6
Manual release lever
7
Safety edge aluminium profile
8
Safety edge rubber profile
9
Safety edge connection box
10
Safety edge connection cable
11
Counterweight belt
12
Modular counterweight
13
Right-hand column cover
2. TECHNICAL CHARACTERISTICS
CONTROL PANEL TRIPHASE (49E)
Power supply voltage ............400 V triphase 50/60 Hz
Power input ............................................................. 6 A
Auxiliary control power voltage ........................24V
Motor rating .......................................... 0,55 ÷ 1,8 KW
Control board protection class ............................ IP 55
Operating temperature .............................. - 5 + 50 °C
Correctly size the line conductor cross-section by referring to the indicated absorption and taking the length and
installation of the cables into account.
5
9
17
19
6
14
16
18
7
8
4
3
2
1
23
24
25
10
Ref. Description
14
Left-hand column cover
15
Right-hand column
16
Left-hand column
17
Curtain aluminium profiles
18
Curtain reinforcing tube
19
Control panel
20
Photocell LAB4
21
Curtain lifting belt
22
Curtain belt attachment
23
Transparent section
24
Polyester section
25
Safety edge protective pocket
CONTROL PANEL INVERTER (52E)
Power supply voltage ........ 230 V monofase 50/60 Hz
Power input ........................................................... 16 A
Auxiliary control power voltage ........................24V
Motor rating .......................................... 0,55 ÷ 1,8 KW
Control board protection class ............................ IP 55
Operating temperature .............................. - 5 + 50 °C
- 31 -
11
12
21
13
15
20
22
EN
0DT829 2016-04-01