5.2 52E CONTROL PANEL (INVERTER) - Connections
52E
Command
1
2
NC
1
3
NO
1
4
NO
41
40
NC
1
8
NC
1
20
NO
1
11
NC
1
13
NC
M2
Safety device / Commands
M3
Position signal
M4
Interlock
M4A
Back
M5
Motor / brake motor
M6
Thermal motor
M7
Absolute encoder
Output
+
1
-
0
LAMP
-F
+F
U W V
M
3 ~
0DT829 2016-04-01
Function
STOP
If on the programming menu (page 15 point 16)
Contact 1-2 enabled, opening of the contact STOPS the door
Opening
The closure of the contact activates the opening operation.
Closure
The closure of the contact activates the closing operation.
Reversal safety
Opening the safety contact triggers a reversal of the movement (reopening)
contact
during the closing operation.
Reversal safety
Opening the safety contact triggers a reversal of the movement (reopening)
contact
during the closing operation.
Partial opening
Closing of the contact activates a partial opening operation of the duration set
with the advanced menu.
Closing position
Opening of the contact indicates the closing position. (max. 50 mA)
Opening position
Opening of the contact indicates the opening position. (max. 50 mA)
CONTROL PANEL CONNECTORS
Value
Power supply to accessories.
24 V = / 0. 5A
Power supply output for external accessories, including automation status
lamps.
Flashing light (LAMP).
230 V~ / 50 W
Activated during opening and closing operations.
Motor electric brake.
24 V = / 0.5 A
The output is active for the duration of both the opening and closing operation.
230 V~ / 6 A
Three-phase motor.
INPUTS
Description
J4
OPEN
SAFETY
OUTPUTS
Description
- 38 -
Brake resistance
Auxiliary panel card
Auxiliary safety card