6.3 Service menu (password required)
The Service menu is used to modify the brake resistance thresholds, the overcurrent threshold
and the anti-wind function when the encoder intervenes.
To access the Service menu:
-
STOP the door
-
Set DIP5 to ON
-
Enter the PW: button sequence OPEN- OPEN- CLOSE- PARTIAL OPENING
STEP
1
level options
st
1
MIN BRAKING VOLT.
(Minimum bus voltage)
Default 340Vdc
2
MAX BRAKING VOLT.
(Adjustment of brake resistance
intervention threshold)
Default 380Vdc
3
OVERCURRENT LIMIT
Default 10A
4
RAMP SLOPE DURING
OPENING
5
ALARM LIST
ONCE PROGRAMMING HAS ENDED, SET DIP5 TO OFF
6.4 Display messages
MESSAGE
Ditec Entrematic
Opening of VBUS IBUS
Door open - automatic closing time
Closing of VBUS IBUS
Input 40 closed; input 8 open
input 40 open; input 8 closed
Thermal or release micro open
Opening safety device activated
Door stopped
6.5 Interlock
Notes
If the BUS voltage falls below this value, a check on the control panel power supply
line is requested (wire section suitable for withstanding the absorbed current.
When the bus voltage decreases, the bus current increases). Varies from 300V
to 350V
Value above which insertion of brake resistance is required.
Varies from 355V to 400V
If the current on the BUS exceeds the set threshold, the door opens at half the
speed to reduce absorption.
Changes the slope of the deceleration ramp when opening. Default 15.
(If the value is increased, the ramp distance is reduced).
The last 50 alarms are displayed: Overcurrent; bus voltage exceeds limit,
Intervention of brake resistance, inverter overtemperature, faulty motor driver
(encoder). To exit, press partial opening
SITUATION
door closed waiting for command
door opening
Door open
door closing
intervention of photocell
intervention of encoder (SLEC)
Intervention of safety micro on manual
opening device / intervention of motor
thermal switch.
photocell engaged when door is closed
and door does not open
stop command activated
DOOR 1
PORTA 1
INPUT
+24V
1 IN NC C NO
M4
+24V
Logical operation
Funzionamento
Logico
- 45 -
ON
1 2 3 4 5 6 7 8
NOTES
When door is moving
When door is moving
Message that only appears if the
"opening safety" function is set to YES
on the advanced menu (step 7).
DOOR 2
PORTA 2
INPUT
1 IN NC C NO
M4
EN
0DT829 2016-04-01