6.2 ADVANCED MENU

The advanced menu allows you to modify the position of the limit switches which have previously been set
and modify the set default parameters.
To access the Advanced Menu:
-
STOP the door
-
Set DIP 2 to ON
"ENCODER CALIB.", the first item in the advanced menu, will appear on the display.
ONCE PROGRAMMING HAS ENDED, SET DIP2 TO OFF
STEP
1
level options
st
1
Encoder Calibration
2
Photocell excluded
(step present only for
Reset doors)
3
Primary safety device
excluded
4
Automatic closing
(default SI with T= 5 s)
5
Automatic closing time
6
Command mode
7
Opening safety device
8
Interlock
9
Pre-flashing when
opening
(default no)
2
level options
nd
by scrolling
or
Closed position
to confirm
by scrolling
Change value
(1 unit ≅ 3mm)
or
to confirm
by scrolling
Change value
(1 unit ≅ 3mm)
or
to confirm
by scrolling
YES
or
to confirm
NO
by scrolling
Time variant
or
to confirm
by scrolling
Impulsive
or
to confirm
Man present
YES
by scrolling
or
to confirm
NO
by scrolling
NO INTERLOCK
or
AIRLOCK
to confirm
INTERLOCK
YES
by scrolling
or
to confirm
NO
- 43 -
ON
1 2 3 4 5 6 7 8
Notes
The door will move to the desired position in
man present mode and at low speed. All the
positions (closing, partial opening, opening)
must be set.
By increasing the value, the position of the
photocell by-pass is raised
By increasing the value, the position of the
primary safety by-pass is raised
Option available only if YES has been
selected for point 4).
Value ranging from 0 to 100 sec.
If set to YES, the closed door that receives
an opening command does not open if the
photocell is activated.
AIRLOCK: door 2 opens with external
command only if door 1 is closed.
INTERLOCK: door 2 opens automatically
when door 1 has closed
Pre-flashing has a set time of
3 sec.
0DT829 2016-04-01