3. Clean the air intake filter in accordance with the
instructions.
4. Protect the apparatus from dust, possibly with a
plastic cover.
5. Store the apparatus in an upright position in a place
where it is protected from dust and direct sunlight.
Filter cleaning
The dehumidifier is equipped with an air intake filter to prevent
damage. To avoid damage to the apparatus or a reduction in
performance, the air intake filter is to be checked and cleaned
when necessary, but at least every two weeks.
1. To switch off the appliance, press the mains switch
so that it is in operating mode '0'.
2. Remove the holder from the air filter.
3. Pull out the air filter.
4. Clean the air intake filter with warm water or
with a vacuum cleaner (diagram G).
5. Remove heavy soiling by washing in warm soapy water,
max. 40 °C. Then rinse in fresh water (diagram G).
6. Please note that the air intake filter must be undamaged
and must be dry before insertion.
The apparatus must never be operated without
an air intake filter installed!
Transportation of the apparatus
The appliance is equipped with lockable wheels and grip
recesses on both sides of the housing. Furthermore, the
appliances can be stacked to save storage space.
When transporting the appliance it must be kept upright and
secured by appropriate means such as lashing straps.
Each time before transporting:
• Before moving the apparatus, switch it off and remove
the mains plug from the socket.
• Then empty the condensate container. Please watch
out for subsequent dripping condensate.
• Do not pull the apparatus by its mains cable.
Care and maintenance
Regular preventative maintenance and observation of certain
prerequisites will guarantee fault-free operation and a long
service life.
After every period of prolonged operation, and at least once per
year, the apparatus should be checked and thoroughly cleaned.
All moving parts have been treated with low-maintenance per-
manent lubrication. The entire refrigeration system is a main-
tenance-free hermetically-sealed system and may only be main-
tained by authorised specialist companies.
The mains plug must be removed from the
mains socket before any work is carried out on
the apparatus!
• Keep the apparatus free from dust or any other deposits.
• Only use a dry or damp cloth to clean the apparatus.
Do not use running water.
• Do not use cleaning agents that are caustic or contain
solvents and only use appropriate cleaning agents even
in the case of heavy soiling.
• Check the air intake filter regularly for fouling.
It should be cleaned or replaced as necessary.
Work on the refrigeration system and the elec-
trical equipment may only be carried out by an
authorised & qualified company!
B - 3
Cleaning the condenser and evaporator
This work requires the apparatus housing to be opened, and
therefore may only be carried out by authorised & qualified
companies!
• Clean the condenser and the evaporator either by blowing
or sucking them through, or by using a soft brush. Do not
use running water.
• Please note that the fins can easily be damaged or bent.
• Carefully clean the inside surfaces of the apparatus, the
condensate pan with hose connection, the ventilator and
the ventilator housing.
• Reinstall all dismounted parts correctly
• Check that the apparatus is functioning correctly
and carry out an electrical safety examination.
Important recycling information!
The apparatus uses the environmentally-friendly and ozone-
neutral refrigerant R-134a. In accordance with legal stipula-
tions, or those that apply locally, the refrigerant/oil mixture used
in the apparatus must be disposed of correctly.
In the European Union electronic equipment must
not be treated as domestic waste, but must be
disposed of professionally in accordance with
Directive 2002/96EU of the European Parliament
and Council of 27th January 2003 concerning old
electrical and electronic equipment.At the end of its life please
dispose of this instrument in a manner appropriate to the
relevant legal requirements.
Troubleshooting
The fault-free operation of the apparatus has been confirmed
by repeated tests at the factory. However, if a loss of function
should occur, please check the apparatus in accordance with
the following list.
The apparatus will not start:
• Check the mains connection. 230 V / 1~ / 50 Hz.
• Check the inbuilt mains fuse.
• Check the mains plug for damage.
The apparatus runs, but no
condensation formation:
• Check the fluid level in the condensate tank.
The 'tank full' indicator lamp must not be lit.
• Check the microswitch of the condensate tank rocker.
• Check the room temperature. The working range
of the apparatus is between 5 and 32 °C.
• Check the air humidity: minimum 35 % relative humidity.
• Check which operating mode is set. The humidity of the
room air in which the unit is operating must be above the
selected range. If necessary, turn the rotary control switch
clockwise towards permanent operation (figure D.5).
• Check the air intake filter for fouling. Clean or replace
it if necessary.
• Have the heat exchanger fins checked for soiling.
This examination requires the apparatus to be opened
up and hence must be carried out by an authorised
specialist company.
The mains plug must be removed from the
mains socket before any work is carried out on
the apparatus.
The apparatus is making a lot of noise or
vibrates, condensate is running out:
• Check that the apparatus is standing upright on
a level surface.
• Have the condensate pan and connection piece
checked for fouling.
Operating manual dehumidifier TTK 140 S
If the apparatus does not function correctly after carrying out the
above checks, please contact an authorised specialist company.
Work on the refrigeration system and the elec-
trical equipment may only be carried out by
a specially authorised & qualified company!
Technical data
Working range temperature
Working range humidity
35 - 100 % relative humidity.
Dehumidifying capacity max.
Dehumidifying capacity (at 30 °C / 80 % R.H.) 32 l/day
Air performance max.
Refrigerant
Refrigerant quantity
Electrical connection
Frequency
Nominal current max.
Power consumption max.
Sound pressure level LpA 1m
1)
Condensate container
Depth
Width
Height
Weight
5 - 32 °C
35 l/day
250 m
3
/h
R-134a
475 g
230 V
50 Hz
3.85 A
0.66 KW
52 dB (A)
7 l
400 mm
380 mm
630 mm
30.5 kg
EN