INSTALLATION
Safety
INSTALLATION
6.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1
General safety instructions
We can only guarantee trouble-free function and operational reli-
ability if original spare parts intended for the appliance are used.
6.2
Regulations, standards and instructions
Note
Observe all applicable national and regional regulations
and instructions.
7.
Appliance description
7.1
Standard delivery
Delivered with the appliance:
- Dummy flange
- additional type plate
7.2
Accessories
7.2.1 Required accessories
Depending on the static pressure, safety assemblies and pressure
reducing valves are available. These type-tested safety assemblies
protect the appliance against unacceptable excess pressure.
7.2.2 Further accessories
In addition, heat exchangers, flanged and threaded immersion
heaters and thermal insulation are available as accessories.
If it is not possible to insert a rod anode from above, install a
segmented anode.
16
| SBP 1000-1500 E | E SOL | E cool
8.
Preparations
8.1
Installation site
f Always install the appliance in a room free from the risk of
f
frost.
f Ensure the floor has sufficient load bearing capacity and
f
evenness (see chapter "Specification / Data table").
f Observe the room height and height when tilted (see chapter
f
"Specification / Data table").
Minimum clearances
≥200
f Maintain the minimum clearances.
f
8.2
Transport
Use the lifting eyes at the top of the appliance to assist handling.
≥200
www.stiebel-eltron.com