Napoleon Vector Serie Manuel D'installation page 25

Masquer les pouces Voir aussi pour Vector Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

see-thru
1" [25mm]
minimum all
sides for vertical
venting.
When passing
through a
ceiling, use
firestop spacer
W500-0028 (not
supplied)
L
minimum clearance
Ref
L
note:
Although the minimum enclosure height for the LV series is 73", some venting configurations that require more
vertical rise will require a larger enclosure to provide minimum vertical clearance between vent pipes and com-
bustibles.
rough framing - before appliance installation
SAFETY BARRIER
LV38-1
LV50-2
73" (185.4cm)
73" (185.4cm)
note:
Shaded components (finish framing) must be
non-combustible materials.
LV62
91" (231.1cm)
91" (231.1cm)
6" [152mm] minimum
3" [76mm] top
2" [51mm] sides /
bottom
0" to non-
combustible finishing
such as brick and
stone
When passing
through a wall, use
firestop spacer
W615-0162 (sup-
plied with W010-
4178 firestop spacer
assembly)
0" to side standoffs
1/2" finishing flange
(4 sides)
0" to base of the
appliance
LV74
W415-1709 / A / 07.27.17
EN
25