Renishaw TS27R Manuel D'installation Et D'utilisation page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Screen
PROBE
Probe + A2
INPUT
Probe – A3
For information regarding
these connections, please
refer to the MI 8-4 user's
guide H-2000-5008
Inspection system input + A4
Inspection system input – A5
Screen A6
A1
Blue
Red
OPTIONAL
Inspection probe
Inspection
probe
interface
Machine reference ground
*
The 100 nF capacitor prevents d.c.
and low frequency a.c. flowing in the
cable screen due to differences in
potential between the controller
reference ground and the machine
reference ground
MACHINE TOOL
TS27R TOOL SETTER
TS27R PROBE
100 nF
*
capacitor
Possible earth
path through base
screws of TS27R
1-9