For model WH-S*C09*3E8
Terminal on the outdoor unit
Colour of wires (Connecting cables)
Terminal on the indoor unit
(Power Supply Cord)
Terminals on the isolating device
from power supply (Disconnecting
means)
For model WH-S*C12*9E8, WH-S*C16*9E8
Terminal on the outdoor unit
Colour of wires (Connecting cables)
Terminal on the indoor unit
(Power Supply Cord)
Terminals on the isolating device
from power supply (Disconnecting
means)
RCCB/ELCB
*1
Holder
(Clamper)
Power Supply Cord
WIRE STRIPPING AND CONNECTING REQUIREMENT
Wire stripping
Indoor/outdoor
connecting
terminal board
5mm or
more
No loose strand
(gap between
when insert
wires)
CONNECTING REQUIREMENT
For WH-S*C09*3E8
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-2.
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3 and can be connected to current supply network.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-2.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-11 and shall be connected to suitable supply network, with the following
maximum permissible system impedance Z
2 is connected only to a supply of that impedance or less.
For WH-S*C12*9E8, WH-S*C16*9E8
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-2.
•
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3 and can be connected to current supply network.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-2.
•
The equipment's Power Supply 2 complies with IEC/EN 61000-3-3 and can be connected to current supply network.
INSTALLATION OF REMOTE CONTROLLER AS ROOM
7
THERMOSTAT
•
Remote Controller 3 mounted to the Indoor Unit can be moved to the room and serve as Room Thermostat.
Installation Location
•
Install at the height of 1 to 1.5 m from the fl oor (Location where average room temperature can be detected).
•
Install vertically against the wall.
•
Avoid the following locations for installation.
1. By the window, etc. exposed to direct sunlight or direct air.
2. In the shadow or backside of objects deviated from the room airfl ow.
3. Location where condensation occurs (The Remote Controller is not moisture proof or drip proof.)
4. Location near heat source.
5. Uneven surface.
•
Keep distance of 1 m or more from the TV, radio and PC. (Cause of fuzzy image or noise)
Main Power Supply
or Main + Backup
Booster Heater
Heater Power Supply
Power Supply
L
L
L
N
L
N
A1
A2
A3
L
L
L
N
L
N
A1
A2
A3
Power Supply 1
Power Supply 2
Booster + Backup
Main Power Supply
Heater Power Supply
L
L
L
N
L
L
A1
A2
A3
B1
L
L
L
N
L
L
A1
A2
A3
B1
Power Supply 1
Power Supply 2
Terminal Board
*1
Connecting Cable
Conductor
fully insert
ACCEPT
= 0.426 at the interface. Please liaise with supply authority to ensure that the Power Supply
max
1
2
3
4
5
1
2
3
4
5
Indoor unit/Outdoor unit
connection
1
2
3
4
5
L
N
1
2
3
4
5
B2
B3
Indoor unit/Outdoor unit
L
N
B2
B3
connection
Terminal screw
M4
M5
*1 - Earth wire must be longer than other cables for safety reasons
Conductor
Conductor not
over insert
fully insert
PROHIBITED
PROHIBITED
Tightening torque cN•m {kgf•cm}
157~196 {16~20}
196~245 {20~25}
7