Listes des paramètres
4.1.10 6-** E/S ana.
Numé
Description du paramètre
ro de
para
mètre
6-0* Mode E/S ana.
6-00
Temporisation/60
4
4
6-01
Fonction/Tempo60
6-1* Entrée ANA 1
6-10
Ech.min.U/born.53
6-11
Ech.max.U/born.53
6-12
Ech.min.I/born.53
6-13
Ech.max.I/born.53
6-14
Val.ret./Réf.bas.born.53
6-15
Val.ret./Réf.haut.born.53
6-16
Const.tps.fil.born.53
6-2* Entrée ANA 2
6-20
Ech.min.U/born.54
6-21
Ech.max.U/born.54
6-22
Ech.min.I/born.54
6-23
Ech.max.I/born.54
6-24
Val.ret./Réf.bas.born.54
6-25
Val.ret./Réf.haut.born.54
6-26
Const.tps.fil.born.54
6-3* Entrée ANA 3
6-30
Ech.min.U/born. X30/11
6-31
Ech.max.U/born. X30/11
6-34
Val.ret./Réf.bas.born.X30/11
6-35
Val.ret./Réf.haut.born.X30/11
6-36
Constante tps filtre borne X30/11
6-4* Entrée ANA 4
6-40
Ech.min.U/born. X30/12
6-41
Ech.max.U/born. X30/12
6-44
Val.ret./Réf.bas.born.X30/12
6-45
Val.ret./Réf.haut.born.X30/12
6-46
Constante tps filtre borne X30/12
6-5* Sortie ANA 1
6-50
S.born.42
6-51
Echelle min s.born.42
6-52
Echelle max s.born.42
6-53
Ctrl bus sortie born. 42
6-54
Tempo préréglée sortie born. 42
6-55
Filtre de sortie borne 42
6-6* Sortie ANA 2
6-60
Sortie borne X30/8
6-61
Mise échelle min. borne X30/8
6-62
Mise échelle max. borne X30/8
6-63
Ctrl par bus sortie borne X30/8
6-64
Tempo prédéfinie sortie borne X30/8
210
®
VLT
AutomationDrive FC 301/302
Valeur par défaut
4-setup
10 s
All set-ups
[0] Inactif
All set-ups
ExpressionLimit
All set-ups
10 V
All set-ups
0.14 mA
All set-ups
20 mA
All set-ups
0 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
ExpressionLimit
All set-ups
10 V
All set-ups
ExpressionLimit
All set-ups
20 mA
All set-ups
0 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
0.07 V
All set-ups
10 V
All set-ups
0 ReferenceFeed-
backUnit
All set-ups
ExpressionLimit
All set-ups
0.001 s
All set-ups
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
[0] Inactif
1 set-up
ExpressionLimit
All set-ups
0 %
All set-ups
100 %
All set-ups
0 %
All set-ups
0 %
1 set-up
Danfoss A/S © 05/2015 Tous droits réservés.
FC 302
Modification
Indice de
uniquement
en cours de
conversion
fonction-
nement
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Type
0
Uint8
-
Uint8
-2
Int16
-2
Int16
-5
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-5
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
MG33MK04