Operating instructions SATA air vision 5000
EN
9.2. Make the breathing protection apparatus ready to use
Drop in air flow
There can be a drop in air flow when a spray gun is operating at the air 
regulator at the same time with the SATA spray air hose 1 m (Art. No.
13870).
→ Set inlet pressure with the trigger of the spray gun fully removed.
→ Holding the trigger guard pressed, increase the working overpressure
at the filter unit until the acoustic warning signal no longer sounds (this 
can vary, depending on spray gun, hose length etc.).
Notice!
The air regulator must be connected to the compressed air supply sys-
tem (see operating instructions for the air regulator).
■ Take the air hose through the belt unit.
■ Adjust the necessary air flow at the air regulator (see operating instruc-
tions for the air regulator).
The breathing protection equipment is operationally ready.
9.3. Adjust breathing air regulation
Notice!
If the standard distribution of air in the visor feels unpleasant, it can
be adjusted by fitting the enclosed deflector [5-1] at the outlet point
[5-2] (see chapter 10.5). The deflector is included in the scope of supply.

10. Maintenance and Care

Spare parts are available for carrying out repairs (see chapter 13).
10.1. Exchange facial seal
Danger from harmful substances
The protection function of the facial seal between face and visor is not
guaranteed due to wear, deformation or damages.
→ Replace the hygiene insert (see chapter 13).
82
Warning!
Warning!