Malfunctions; Corrective Action - SATA air vision 5000 Mode D'emploi

Masquer les pouces Voir aussi pour air vision 5000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 113
Operating instructions SATA air vision 5000
EN
10.4. Exchange comfort head band.
The comfort bands [9-1] for the forehead and head band are fastened by
the bend when fitted.
Remove comfort head band.
Notice!
Mark the position of the head fixation at the front fixing tabs [4-1].
■ Remove the head straps from the hood shell by loosening the front and
rear assembly flaps.
■ Remove the comfort head band [9-1] from the head straps [9-2].
■ Clean/disinfect the forehead side of the head straps.
Attach new comfort head band.
■ Fold the new comfort head band [9-3] around the head straps flaps 
[9-4] between the two front assembly flaps.
■ Insert the head straps in the hood shell as marked on the assembly
flaps. Ensure the breathing protection hood is seated properly.
10.5. Insert air guide element
Notice!
The air volume flow inside the breathing protection hood can be found to 
be annoying.
■ If necessary, insert the deflector [5-1] with the four noses in the intend-
ed grooves [5-2].

11. Malfunctions

The following table describes malfunctions, their causes and correspond-
ing remedies.
If it is not possible to remedy the malfunctions with the described correc-
tive action, send the breathing protection apparatus to the SATA customer
service department. (For address see chapter 12).
Malfunction
Visor foil will not hold
Facial seal does not
seal properly
84
Cause
Visor bolt is broken off Attach new visor bolt.
Facial seal defective

Corrective action

Attach new facial seal

Publicité

Table des Matières
loading

Table des Matières