Technical Data; First Use - SATA air vision 5000 Mode D'emploi

Masquer les pouces Voir aussi pour air vision 5000:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 113

7. Technical Data

Description
Required operating pressure
without spray gun
Necessary operating pressure
with spray gun (in combination
with 20 m spray air hose Art. No.
13870)
Max. operating pressure
Required minimum volume flow
Maximum flow rate (6.0 bar, air 
regulator open wide)
Operating temperature
Storage temperature
Weight
Operating pressure of com-
pressed air safety tube

8. First Use

The breathing protection hood is delivered in an assembled and opera-
tionally ready state.
Check after unpacking:
■ Breathing protection hood damaged.
■ Scope of supply complete (see chapter 5).
8.1. Personalise breathing protection hood
The breathing protection hood can be personalised with two CCS disks
[3-2]. The hood is supplied ex works with two red CCS disks on the right
and left bolt [3-1] of the visor.
■ Push the CCS-disks out from the inside of the hood and replace it with
CCS-disks of different colours.
8.2. Adjust head straps
The head straps have four adjustment possibilities for the individual ad-
justment to the wearer. To adjust the head straps, remove them from the
hood shell as follows.
■ Remove the hood cover [2-15] and open the visor [2-6].
■ Undo the rear fixing tabs [4-3] and release the front fixing tabs [4-1].
■ Remove head straps.
Operating instructions SATA air vision 5000
2,5 bar – 3,0 bar 35 psi - 44 psi
4,0 bar – 6,0 bar 58 psi - 87 psi
5 °C – 60 °C
-20 °C – 60 °C
max. 10,0 bar
10,0 bar
150 Nl/min
740 Nl/min
41 °F – 140 °F
ca. 975 g
145 psi
5,3 cfm
26,1 cfm
-4 °F – 140 °F
ca. 34,4 oz.
max. 145 psi
EN
79

Publicité

Table des Matières
loading

Table des Matières